Objectives: To assess perceptual benefits provided by the improved spatial resolution and noise performance of deep silicon photon-counting CT (Si-PCCT) over conventional energy-integrating CT (ECT) using polychromatic images for various clinical tasks and anatomical regions.
Materials And Methods: Anthropomorphic, computational models were developed for lungs, liver, inner ear, and head-and-neck (H&N) anatomies. These regions included specific abnormalities such as lesions in the lungs and liver, and calcified plaques in the carotid arteries. The anatomical models were imaged using a scanner-specific CT simulation platform (DukeSim) modeling a Si-PCCT prototype and a conventional ECT system at matched dose levels. The simulated polychromatic projections were reconstructed with matched in-plane resolutions using manufacturer-specific software. The reconstructed pairs of images were scored by radiologists to gauge the task-specific perceptual benefits provided by Si-PCCT compared to ECT based on visualization of anatomical and image quality features. The scores were standardized as z-scores for minimizing inter-observer variability and compared between the systems for evidence of statistically significant improvement (one-sided Wilcoxon rank-sum test with a significance level of 0.05) in perceptual performance for Si-PCCT.
Results: Si-PCCT offered favorable image quality and improved visualization capabilities, leading to mean improvements in task-specific perceptual performance over ECT for most tasks. The improvements for Si-PCCT were statistically significant for the visualization of lung lesion (0.08 ± 0.89 vs. 0.90 ± 0.48), liver lesion (-0.64 ± 0.37 vs. 0.95 ± 0.55), and soft tissue structures (-0.47 ± 0.90 vs. 0.33 ± 1.24) and cochlea (-0.47 ± 0.80 vs. 0.38 ± 0.62) in inner ear.
Conclusions: Si-PCCT exhibited mean improvements in task-specific perceptual performance over ECT for most clinical tasks considered in this study, with statistically significant improvement for 6/20 tasks. The perceptual performance of Si-PCCT is expected to improve further with availability of spectral information and reconstruction kernels optimized for high resolution provided by smaller pixel size of Si-PCCT. The outcomes of this study indicate the positive potential of Si-PCCT for benefiting routine clinical practice through improved image quality and visualization capabilities.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10922475 | PMC |
http://dx.doi.org/10.1016/j.ejrad.2023.111279 | DOI Listing |
J Exp Psychol Hum Percept Perform
January 2025
School of Psychology, University of Sussex.
Human listeners have a remarkable capacity to adapt to severe distortions of the speech signal. Previous work indicates that perceptual learning of degraded speech reflects changes to sublexical representations, though the precise format of these representations has not yet been established. Inspired by the neurophysiology of auditory cortex, we hypothesized that perceptual learning involves changes to perceptual representations that are tuned to acoustic modulations of the speech signal.
View Article and Find Full Text PDFActa Neuropsychiatr
January 2025
IRCCS Ospedale Policlinico San Martino, Genoa, Italy.
Objective: Time distortions characterise severe mental disorders, exhibiting different clinical and neurobiological manifestations. This systematic review aims to explore the existing literature encompassing experimental studies on time perception in patients with bipolar disorder (BD), considering psychopathological and cognitive correlates.
Methods: Studies using an experimental paradigm to objectively measure the capacity to judge time have been searched for.
Front Robot AI
January 2025
Department of Materials and Production, Aalborg University, Aalborg, Denmark.
Object pose estimation is essential for computer vision applications such as quality inspection, robotic bin picking, and warehouse logistics. However, this task often requires expensive equipment such as 3D cameras or Lidar sensors, as well as significant computational resources. Many state-of-the-art methods for 6D pose estimation depend on deep neural networks, which are computationally demanding and require GPUs for real-time performance.
View Article and Find Full Text PDFPLoS One
January 2025
Academic Partnership Unit, Leeds Trinity University, Leeds, United Kingdom.
The fast-bowling action demands repetitive high-intensity whole body movements, imposing complex physical and perceptual demands on players that vary significantly throughout the season. This study aimed to assess and establish practical methods and metrics for quantifying fatigue after four simulated fast bowling spells. Eleven senior club male fast bowlers (age 27.
View Article and Find Full Text PDFJ Acoust Soc Am
January 2025
Dyson School of Design Engineering, Imperial College London, SW7 2DB London, United Kingdom.
To date, there is strong evidence indicating that humans with normal hearing can adapt to non-individual head-related transfer functions (HRTFs). However, less attention has been given to studying the generalization of this adaptation to untrained conditions. This study investigated how adaptation to one set of HRTFs can generalize to another set of HRTFs.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!