This article introduces a novel unlabeled surface-enhanced electrochemiluminescence (SEECL) sensor for malachite green (MG) detection. The SEECL sensor was prepared by modifying the Ru(bpy) doped gold-SiO core-shell nanocomposites (Au@SiO-Ru(bpy)) on the gold electrode. Ru(bpy) of nanocomposites can not only emit electrochemiluminescence (ECL) with electrochemical reaction, but also induce the local surface plasmon resonance (LSPR) of gold core. That is beneficial to enhance the ECL signa of sensor. However, in the existence of MG, the luminescence of sensor would be quenched by the fluorescence resonance energy transfer (FRET) between MG and Ru(bpy). In this paper, both fluorescence and ECL of the Au@SiO-Ru(bpy) were investigated for MG detection. And the results show that the SEECL sensor has high sensitive to MG. Under the optimal experimental conditions, the minimum detection concentration could be achieved about 1.0 nM of MG, which fully meets the China national standard detection requirements of veterinary drug residue in seafood.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s10895-023-03563-y | DOI Listing |
Anal Chim Acta
June 2024
MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China; Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, 510631, China. Electronic address:
Background: Colorimetric lateral flow immunoassay (LFIA) is a widely used point-of-care testing (POCT) technology, while it has entered a bottleneck period because of low detection sensitivity, expensive preparation materials, and incapable quantitative detection. Therefore, it is necessary to develop a novel POCT method that is ultrasensitive, simple, portable, and capable of accurately detecting biomarkers in biofluids daily, particularly for pregnancy preparation and early screening of diseases.
Result: In this work, a novel dry chemistry-based self-enhanced electrochemiluminescence (DC-SE-ECL) LFIA sensor is introduced for accurate POCT of luteinizing hormone (LH).
Biosens Bioelectron
August 2024
Department of Bioengineering, McGill University, Montreal, Canada. Electronic address:
Electrochemiluminescence (ECL) is a bioanalytical technique with numerous advantages, including the potential for high temporal and spatial resolution, a high signal-to-noise ratio, a broad dynamic range, and rapid measurement capabilities. To reduce the complexity of a multi-electrode approach, we use a single-electrode electrochemiluminescence (SE-ECL) configuration to achieve the simultaneous emission and detection of multiple colors for applications that require multiplexed detection of several analytes. This method exploits intrinsic differences in the electric potential applied along single electrodes built into electrochemical cells, enabling the achievement of distinct colors through selective excitation of ECL luminophores.
View Article and Find Full Text PDFJ Fluoresc
January 2024
Fujian Vocational College of Bioengineering, Fuzhou, Fujian Province, 350002, China.
This article introduces a novel unlabeled surface-enhanced electrochemiluminescence (SEECL) sensor for malachite green (MG) detection. The SEECL sensor was prepared by modifying the Ru(bpy) doped gold-SiO core-shell nanocomposites (Au@SiO-Ru(bpy)) on the gold electrode. Ru(bpy) of nanocomposites can not only emit electrochemiluminescence (ECL) with electrochemical reaction, but also induce the local surface plasmon resonance (LSPR) of gold core.
View Article and Find Full Text PDFAnalyst
October 2020
Ministry of Education Key Laboratory for Analytical Science of Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian Province 350116, China.
The detection of biomarkers in exhaled breath condensates (EBCs) is regarded as a promising non-invasive diagnostic approach. However, the ultralow concentration of biomarkers in EBCs is a great challenge. Herein, a sensitive dual signal amplification strategy was developed based on surface-enhanced electrochemiluminescence (SEECL) combined with resonance energy transfer (RET).
View Article and Find Full Text PDFAnalyst
December 2019
Fujian Vocational College of Bioengineering, Fuzhou, Fujian Province 350002, China.
This study reports a surface-enhanced electrochemiluminescence (SEECL) sensor for the ultrasensitive detection of prostate-specific antigen (PSA) in human serum. First, we prepared the Au-SiO2 core-shell nanocomposites doped with Ru(bpy)32+ (Au@SiO2-Ru) as the ECL signal generation and amplification element of the SEECL sensor. Ru(bpy)32+ could emit ECL under the excitation of an electrochemical reaction, and generate the local surface plasmon resonance (LSPR) electromagnetic field from the gold nanoparticle (AuNP) core.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!