Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
We analyzed the intraoperative kinematics of total knee arthroplasty (TKA) using a navigation system to investigate the influence of different inserts on kinematics. This was a retrospective observational study. The Vanguard individualized design (33 patients, 33 knees) XP and anterior-stabilized (AS) inserts were used in TKA for osteoarthritis. Kinematic data were intraoperatively recorded. The range of motion, tibiofemoral rotational angle, anteroposterior translation of the femur, and varus-valgus laxity were compared between the two inserts (XP vs. AS). There was no significant difference in the range of motion (extension: XP, 3.7° ± 3.3° vs. AS, 3.8° ± 3.3°, = 0.84; flexion: XP, 138.1° ± 10.2° vs. AS, 139.0° ± 13.3°, = 0.73). With the AS insert, the tibia was gradually internally rotated as the knee was flexed. At maximum extension, the internal rotation was smallest with AS (XP 6.5° ± 4.0° vs. AS 5.1° ± 3.4°, = 0.022), which was also associated with smaller anterior femoral translation (maximum extension: XP, 14.1 ± 4.8 mm vs. AS, 11.3 ± 4.7 mm, = 0.00036; 30°: XP, 23.7 ± 5.6 mm vs. AS, 20.7 ± 5.1 mm, = 0.000033; 45°: XP, 24.4 ± 4.9 mm vs. AS, 23.2 ± 4.5 mm, = 0.0038). The AS was associated with a lower varus-valgus laxity (30° XP 4.1° ± 3.4 vs. AS 3.3° ± 2.7°, = 0.036; 60°: XP, 3.2° ± 3.0° vs. AS, 2.4° ± 3.3°, = 0.0089). The AS insert facilitated sequential tibiofemoral rotation with varus-valgus stability in mid-flexion without restricting the range of motion.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1055/a-2240-3336 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!