Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
The generation and presence of excessive hypochlorous acid derivative ionic form (ClO) could cause various diseases, such as arteriosclerosis, DNA damage, and cardiovascular illness. It is a critical need to develop a highly sensitive sensor for reliable detection of ClO in cells and water-soluble systems. In this work, a hydroxyl group has been introduced into the compound 2-amino-3-(((E)-4-(2-(2-(2-hydroxyethoxy)ethyl)-1,3-dioxo-2,3-dihydro-1H-benzo[de]isoquinolin-6-yl)benzylidene)amino)maleonitrile (NDC) to increase its solubility in water, at the same time, the hydrazone unit was designed as a specific recognition group for the "off-on" fluorescence probe of ClO. The probe NDC presents high selectivity, sensitivity, anti-interference, and low detection limit (67 nM) for ClO. The recognition mechanism that ClO breaks the C=N bond and forms the fluorescent compound 4-(2-(2-(2-hydroxyethoxy)ethyl)-1,3-dioxo-2,3-dihydro-1H-benzo[de]isoquinolin-6-yl)benzaldehyde (ND-3) has been confirmed by time-of-flight mass spectrometry. The probe NDC presents a good performance in the actual test of water samples and can be designed as the test papers for the quick and convenient detection of ClO range from 0 to 1 μM. Moreover, the practical application was demonstrated by the successful imaging of endogenous and exogenous ClO in HeLa cells. Our fluorescent biomass-based platform opens vast possibilities for repeatability, sensitivity, and selectivity detection of ClO in cells and water-soluble systems.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1177/00037028231219524 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!