While radiation exposure in foot and ankle surgery varies by procedure, attempts to minimize this hazard remain imperative to protect patients and surgeons. Hindfoot deformity correction employs significant radiation through intraoperative fluoroscopy, however, a paucity of data exists concerning Charcot reconstruction. This investigation describes and compares radiation exposure across varying Charcot pathology and fixation constructs. A retrospective chart review of patients undergoing midfoot Charcot reconstruction under large C-arm assistance from 2016-2022 was conducted. Demographics, pathology-specific, and intervention-specific variables were recorded and compared among midfoot reconstructions. The threshold for statistical significance was set at p ≤ .05. Among 40 patients, the average midfoot radiation exposure and fluoroscopy times were 9.5 ± 5.39 mGy and 256.64 ± 130.67 seconds, respectively. There existed no statistically significant difference in radiation exposure (p = .32) or fluoroscopy times (p = .71) among the different midfoot constructs. There existed a statistically significant relationship between radiation exposure with weight (p = .01) body mass index (p = .03) and number of stages (p = .04). Similarly, a relationship existed between fluoroscopy time with weight (p = .02), body mass index (p = .03), and number of beams/screws (p = .003). Due to the complexity of Charcot reconstruction coupled with multiple robust types of fixation, surgeons must remain cognizant of fluoroscopy usage. Moreover, providers who routinely perform Charcot reconstruction should wear personal protective equipment to protect against radiation.

Download full-text PDF

Source
http://dx.doi.org/10.1053/j.jfas.2024.01.003DOI Listing

Publication Analysis

Top Keywords

radiation exposure
24
charcot reconstruction
20
midfoot charcot
8
exposure fluoroscopy
8
fluoroscopy times
8
existed statistically
8
weight body
8
body mass
8
mass number
8
radiation
7

Similar Publications

Aims: Which is the best extensile lateral (ELA) or sinus tarsi (STA) approach for osteosynthesis displaced intraarticular calcaneal fracture (DIACF) is still debatable. The current RCT's primary objective was to compare the complications incidence after open reduction and internal fixation of DIACFs through STA vs. ELA.

View Article and Find Full Text PDF

Associations between heavy metal exposure and vascular age: a large cross-sectional study.

J Transl Med

January 2025

Department of Cardiology, Tongji Hospital, School of Medicine, Tongji University, No. 389 Xincun Road, Shanghai, 200065, China.

Background: Heavy metal exposure is an emerging environmental risk factor linked to cardiovascular disease (CVD) through its effects on vascular ageing. However, the relationship between heavy metal exposure and vascular age have not been fully elucidated.

Methods: This cross-sectional study analyzed data from 3,772 participants in the National Health and Nutrition Examination Survey (NHANES) from 2005 to 2016.

View Article and Find Full Text PDF

Comparison of single-catheter with two-catheter concept in older female patients undergoing transradial coronary angiography.

Herz

January 2025

Faculty of Medicine, Department of Cardiology, Bilecik Şeyh Edebali University, Pelitözü Mahallesi Fatih Sultan Mehmet Blv. No. 27 Merkez, Bilecik, Turkey.

Background: The aim of this study was to compare the efficacy outcomes of the traditional Judkins left and right catheters with those of the recently introduced Tiger catheter in female participants aged 65 years and older who underwent transradial coronary angiography.

Methods: A cohort of 160 female patients aged 65 and older who were scheduled for coronary angiography (CAG) were divided into two groups according to the use of Tiger (n = 80) or Judkins (n = 80) catheters for radial angiography at a ratio of 1:1, respectively. We analyzed the effectiveness of the Tiger and Judkins catheters, the incidence of catheter failure, contrast volume, CAG time, fluoroscopy time, dose-area product (in mGy/cm), and the occurrence of radial spasm.

View Article and Find Full Text PDF

Radionuclides used for imaging and therapy can show high molecular specificity in the body with appropriate targeting ligands. We hypothesized that local energy delivered by molecularly targeted radionuclides could chemically activate prodrugs at disease sites while avoiding activation in off-target sites of toxicity. As proof of principle, we tested whether this strategy of radionuclide-induced drug engagement for release (RAiDER) could locally deliver combined radiation and chemotherapy to maximize tumor cytotoxicity while minimizing off-target exposure to activated chemotherapy.

View Article and Find Full Text PDF

Low-dose radiation ameliorates PM2.5-induced lung injury through non-canonical TLR1/TLR2-like receptor pathways modulated by Akkermansia muciniphila.

Ecotoxicol Environ Saf

January 2025

NHC Key Laboratory of Radiobiology, School of Public Health, Jilin University, Changchun, Jilin 130021, PR China. Electronic address:

Exposure of PM2.5 can cause different degrees of lung injury, which is referred with inflammatory response. Some evidences showed that low-dose radiation (LDR) induces hormesis in immune, however, it is unknown if LDR ameliorates the PM2.

View Article and Find Full Text PDF