AI Article Synopsis

  • The study tracked the incidence of severe aortic stenosis (AS) in Olmsted County, MN, from 1997 to 2016, finding a stable rate of approximately 52.5 cases per 100,000 patients per year despite an increasing overall number due to population growth.
  • Incidence trends revealed that while rates in men remained stable, there was a decline in women, indicating potential differences in disease presentation or diagnosis between genders.
  • Aortic valve replacement (AVR) procedures became more timely over the two decades, associated with improved survival rates, but overall mortality rates after treatment remained high, highlighting ongoing challenges in managing severe AS.

Article Abstract

Background And Aims: Severe aortic stenosis (AS) is the guideline-based indication for aortic valve replacement (AVR), which has markedly increased with transcatheter approaches, suggesting possible increasing AS incidence. However, reported secular trends of AS incidence remain contradictory and lack quantitative Doppler echocardiographic ascertainment.

Methods: All adults residents in Olmsted County (MN, USA) diagnosed over 20 years (1997-2016) with incident severe AS (first diagnosis) based on quantitatively defined measures (aortic valve area ≤ 1 cm2, aortic valve area index ≤ 0.6 cm2/m2, mean gradient ≥ 40 mmHg, peak velocity ≥ 4 m/s, Doppler velocity index ≤ 0.25) were counted to define trends in incidence, presentation, treatment, and outcome.

Results: Incident severe AS was diagnosed in 1069 community residents. The incidence rate was 52.5 [49.4-55.8] per 100 000 patient-year, slightly higher in males vs. females and was almost unchanged after age and sex adjustment for the US population 53.8 [50.6-57.0] per 100 000 residents/year. Over 20 years, severe AS incidence remained stable (P = .2) but absolute burden of incident cases markedly increased (P = .0004) due to population growth. Incidence trend differed by sex, stable in men (incidence rate ratio 0.99, P = .7) but declining in women (incidence rate ratio 0.93, P = .02). Over the study, AS clinical characteristics remained remarkably stable and AVR performance grew and was more prompt (from 1.3 [0.1-3.3] years in 1997-2000 to 0.5 [0.2-2.1] years in 2013-16, P = .001) but undertreatment remained prominent (>40%). Early AVR was associated with survival benefit (adjusted hazard ratio 0.55 [0.42-0.71], P < .0001). Despite these improvements, overall mortality (3-month 8% and 3-year 36%), was swift, considerable and unabated (all P ≥ .4) throughout the study.

Conclusions: Over 20 years, the population incidence of severe AS remained stable with increased absolute case burden related to population growth. Despite stable severe AS presentation, AVR performance grew notably, but while declining, undertreatment remained substantial and disease lethality did not yet decline. These population-based findings have important implications for improving AS management pathways.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurheartj/ehad887DOI Listing

Publication Analysis

Top Keywords

trends incidence
12
aortic valve
12
incidence rate
12
incidence
10
severe aortic
8
aortic stenosis
8
secular trends
8
markedly increased
8
incident severe
8
valve area
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!