Cardiovascular pressure sensors require dedicated, reliable, and customisable performance testing equipment. Devices available on the market, such as pulsatile pumps and pulse multipliers, offer limited adaptability to the needs of pressure sensor testing or are highly complex tools designed for other purposes. Therefore, there is a strong need to provide an adaptable and versatile device for characterisation during prototype development, prior to animal model testing. Early development requires detailed characterisation of a sensor performance in a realistic environmental scenario. To address this need, we adapted an off-the-shelf pressure chamber with a custom Arduino-based controller to achieve a rapid change in pressure that simulates the pulsatile profile of human blood pressure. The system is a highly customisable tool, and we have experimentally shown that it works successfully in a wide range of pressures from 30 mmHg to 400 mmHg with a resolution of 2 mmHg. By adjusting the chamber volume using a water balloon, we achieved a cycle rate of up to 120 beats per minute. The device can be operated directly from the Arduino IDE or with a customised graphical user interface developed by our research group. The proposed system is intended to assist other researchers in the development of industrial and biomedical pressure sensors.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10767264 | PMC |
http://dx.doi.org/10.1016/j.ohx.2023.e00500 | DOI Listing |
Biosensors (Basel)
December 2024
School of Science, Harbin Institute of Technology (Shenzhen), University Town, Shenzhen 518055, China.
Sarcopenia has been a serious concern in the context of an increasingly aging global population. Existing detection methods for sarcopenia are severely constrained by cumbersome devices, the necessity for specialized personnel, and controlled experimental environments. In this study, we developed an innovative wearable fabric system based on conductive fabric and flexible sensor array.
View Article and Find Full Text PDFBiosensors (Basel)
November 2024
Department of Chemistry, University of Waterloo, 200 University Ave West, Waterloo, ON N2L 3G1, Canada.
Hypoxia, characterized by inadequate tissue oxygenation, may result in tissue damage and organ failure if not addressed. Current detection approaches frequently prove insufficient, depending on symptoms and rudimentary metrics such as tissue oxygenation, which fail to comprehensively identify the onset of hypoxia. The European Pressure Ulcer Advisory Panel (EPUAP) has recognized sweat lactate as a possible marker for the early identification of decubitus ulcers, nevertheless, neither sweat lactate nor oxygenation independently provides an appropriate diagnosis of hypoxia.
View Article and Find Full Text PDFJMIR Med Inform
December 2024
Center for Geriatrics & Gerontology, Taichung Veterans General Hospital, 1650 Taiwan Boulevard Sect 4, Taichung, 407219, Taiwan, 886 4-2359-2525, 886 4-2359-5046.
Background: Telehealth programs and wearable sensors that enable patients to monitor their vital signs have expanded due to the COVID-19 pandemic. The electronic National Early Warning Score (e-NEWS) system helps identify and respond to acute illness.
Objective: This study aimed to implement and evaluate a comprehensive telehealth system to monitor vital signs using e-NEWS for patients receiving integrated home-based medical care (iHBMC).
Cureus
November 2024
Surgery, McGill University, Montreal, CAN.
Compartment syndrome (CS) arises from various etiologies but is most commonly associated with severe traumatic injuries. It is a difficult diagnosis to make in a timely fashion because clinical signs and symptoms are subjective. Missing the diagnosis is a devastating mistake for the patient and the physician.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
College of Electrical and Information Engineering, SANYA Offshore Oil and Gas Research Institute, Northeast Petroleum University, Daqing 163318, China.
Integrating ZnS:Cu@AlO/polydimethylsiloxane (PDMS) flexible matrices with optical fibers is crucial for the development of practical passive sensors. However, the fluorescence coupling efficiency is constrained by the small numerical aperture of the fiber, leading to a reduction in sensor sensitivity. To mitigate this limitation, a microsphere lens was fabricated at the end of the multimode fiber, which resulted in a 21.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!