Background: Surface remineralization is recommended for the management of active non-cavitated interproximal carious lesions in primary teeth. According to the American Academy of Pediatric Dentistry, a recently recognized category of materials called bioactive restorative materials can be used for remineralization. This study aimed to evaluate the release of fluoride (F), calcium (Ca) and phosphate (P) ions from Predicta® Bioactive Bulk-fill composite compared with EQUIA Forte® and Filtek™ Z350 and to determine the remineralization effect of these 3 restorative materials on adjacent initial interproximal enamel carious lesions.

Methods: The release of F, Ca and P ions from 3 groups ((n = 10/group) (Group 1- Predicta®, Group 2- EQUIA Forte® and Group 3- Filtek™ Z350)) was determined at 1st, 4th, 7th and 14th days. After creating artificial carious lesions, human enamel samples were randomly assigned into 3 groups (n = 13/group) which were placed in contact with occluso-proximal restorative materials and exposed to a 14-day pH cycling period. Surface microhardness was determined using a Knoop microhardness assay at baseline, after artificial carious lesions formation and after pH cycling. The difference in the percentage of surface microhardness recovery (%SMHR) among groups was compared. Mineral deposition was analyzed with energy-dispersive x-ray spectroscopy (EDS) and the enamel surface morphology was evaluated with scanning electron microscopy (SEM). Kruskal-Wallis's test with Dunn's post hoc test and one-way ANOVA with Tukey's post hoc test were used for data analysis.

Results: EQUIA Forte® released the highest cumulative amount of F and P ions, followed by Predicta® and Filtek™ Z350. Predicta® released higher amount of Ca ions than EQUIA Forte® and Filtek™ Z350. Predicta® demonstrated the highest %SMHR, followed by EQUIA Forte® and Filtek™ Z350. There was a significant difference in the %SMHR between Predicta® and Filtek™ Z350 (p < 0.05). However, EQUIA Forte® demonstrated the highest fluoride content, followed by Predicta® and Filtek™ Z350. The SEM images of EQUIA Forte® and Predicta® revealed the greater mineral deposition.

Conclusion: Predicta® demonstrated a marked increase in surface microhardness and fluoride content of adjacent initial interproximal enamel carious lesions in primary molars compared with Filtek™ Z350. Predicta® is an alternative restorative material to remineralize adjacent initial interproximal enamel carious lesions in primary molars, especially in high-risk caries patients.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10771692PMC
http://dx.doi.org/10.1186/s12903-023-03814-1DOI Listing

Publication Analysis

Top Keywords

filtek™ z350
24
equia forte®
20
carious lesions
16
restorative materials
12
forte® filtek™
12
interproximal enamel
8
enamel carious
8
lesions primary
8
bioactive bulk-fill
8
bulk-fill composite
8

Similar Publications

Coating Agents for Resin Composites: Effect on Color Stability, Roughness, and Surface Micromorphology Subjected to Brushing Wear.

Oper Dent

January 2025

*Roberta Tarkany Basting, DDS, MSc, PhD, Professor, Restorative Dentistry Department, Faculdade São Leopoldo Mandic, São Paulo, Brazil.

This study evaluated the influence of six resin composite coating agents on color stability and surface roughness after toothbrushing abrasion. Discs (Ø6 mm x 2 mm) of nanofilled resin composite (Filtek Z350XT) were prepared for application of coating agents (n=10): control (absence), two surface sealants (PermaSeal and BisCover LV), two adhesive systems (Scotchbond Multi-Purpose Adhesive/3M Oral Care and Single Bond Universal), and two modeling liquids (Modeling Resin and Composite Wetting Resin). CIELab*, WID, and color change (ΔEab, ΔE00, and ΔWID) were analyzed at baseline, after finishing and polishing, after application of coating agents, after coffee staining (simulating 30 days and one year of staining), and after toothbrushing abrasion.

View Article and Find Full Text PDF

Objective:  Continuous advancements in composite resin materials have revolutionized and expanded its clinical use, improving its physical and mechanical properties. Attaining and retaining surface texture and gloss are crucial for the long-term durability of the composite resin material. This study investigated the supra-nanospherical filler composite material compared with different composite resin materials immersed in different beverages.

View Article and Find Full Text PDF

Purpose: This study aimed to investigate the effect of chlorhexidine (CHX) cavity disinfectant on interfacial microleakage and micro-tensile bond strength (μTBS) of a universal adhesive bonded to dentin in both self-etch (SE) and etch-and-rinse (ER) modes.

Methods: Class I cavities were prepared in the coronal dentin of extracted human teeth and assigned to two etching modes (SE or ER), then subdivided by disinfection with or without CHX (n = 5). Cavities were restored using Single Bond Universal Adhesive and Filtek Z350 XT composite.

View Article and Find Full Text PDF

Evaluation of the Effect of Applying Chitosan, Neem, Tulsi, Aloe vera, and Chlorhexidine Solutions on the Shear Bond Strength of Composite to Dentin.

J Dent (Shiraz)

December 2024

Postgraduate Student, Dept. of Operative Dentistry, Biomaterials Research Center, School of Dentistry, Shiraz University of Medical Sciences, Shiraz, Iran.

Statement Of The Problem: Dentin adhesion is challenging and needs modifications. Newly introduced nature-derived materials may be a useful solution in improving dentin adhesion. The use of natural antimicrobial agents for pretreating prepared dentin surfaces before restoration has become of interest.

View Article and Find Full Text PDF

Shear Bond Strength of Self-Adhesive Versus Conventional Flowable Composites: An Study.

J Int Soc Prev Community Dent

October 2024

Department of Data Science, Prasanna School of Public Health, Manipal Academy of Higher Education, Manipal, Karnataka, India.

Aim: As an emerging yet underexplored innovation in dentistry, self-adhesive flowable composites (SAFCs) represent a promising and enduring advancement in the dental material technology. Our study aims to evaluate the shear bond strength of two SAFCs and the bonding of conventional flowable composite (CFC) to permanent dentin.

Materials And Methods: Thirty-six teeth were embedded in acrylic blocks, with the occlusal third removed to expose the underlying dentin.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?