Magneto-Mechanical Coupling Study of Magnetorheological Elastomer Thin Films for Sensitivity Enhancement.

ACS Sens

Shanxi Key Laboratory of Micro Nano Sensors & Artificial Intelligence Perception, College of Information and Computer, Taiyuan University of Technology, Taiyuan 030024, China.

Published: January 2024

AI Article Synopsis

  • * The study introduced magnetostrictive particles (MSPs) into MREFs, improving their sensitivity and mechanical properties compared to standard versions.
  • * A new formula was developed to describe the nonlinear relationship between magnetic fields and MREFs' performance, leading to a biosensor that detects low levels of human serum albumin with better sensitivity and faster response times than existing biosensors.

Article Abstract

Magnetorheological elastomer thin films (MREFs) exhibit remarkable deformability and an adjustable modulus under magnetic fields, rendering them promising in fields such as robotics, flexible sensors, and biomedical engineering. Here, we fabricated MREF by introducing magnetostrictive particles (MSPs) and evaluated the magneto-mechanical coupling effect on the enhancement of sensitivity. The saturation magnetization () in a parallel anisotropic TbDyFe-PDMS MREF was 5.8 emu/g, and the initial tensile modulus was 55% greater than that of an Iso MREF. We propose a nonlinear magnetorheological formula on the magnetostriction effect, incorporating magnetic dipole interactions and the nonlinear prestress of magnetic particles. This formula highlights the complex nonlinear relationship between the external magnetic field () and the key parameters that affect the enhanced MR effect of MSPs-MREF, such as saturation magnetization, remanence (), magnetostriction constant () and stress deviator in ferromagnetic particles () in the magnetic chain structure. Furthermore, we validate the influence of the key parameters of the rectified magnetorheological formula on a nonlinear magneto-mechanical behavior of MSPs-MREF in PDMS-based MSPs-MREF models by using finite-element simulations. Finally, we developed a biosensor based on MSPs-MREF to detect human serum albumin at low concentrations in human urine samples. There is a 4-fold increase in sensitivity, a lower detection of limit (0.442 μg/mL), and a faster response time (15 min) than traditional biosensors, which in the future might provide an effective way of detecting biomolecules of low concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acssensors.3c02171DOI Listing

Publication Analysis

Top Keywords

magneto-mechanical coupling
8
magnetorheological elastomer
8
elastomer thin
8
thin films
8
saturation magnetization
8
magnetorheological formula
8
key parameters
8
low concentrations
8
magnetic
5
coupling study
4