AI Article Synopsis

  • Assessment of left ventricular diastolic function is crucial for diagnosing and predicting outcomes in heart diseases, particularly in heart failure with preserved ejection fraction.
  • Researchers developed an AI-enabled ECG model, which was tested on nearly 100,000 patients to identify diastolic dysfunction and increased filling pressure, demonstrating strong diagnostic accuracy.
  • The AI-ECG showed good prognostic value, predicting higher mortality rates associated with increased filling pressure, making it a promising tool for improving detection of related cardiac conditions.

Article Abstract

Assessment of left ventricular diastolic function plays a major role in the diagnosis and prognosis of cardiac diseases, including heart failure with preserved ejection fraction. We aimed to develop an artificial intelligence (AI)-enabled electrocardiogram (ECG) model to identify echocardiographically determined diastolic dysfunction and increased filling pressure. We trained, validated, and tested an AI-enabled ECG in 98,736, 21,963, and 98,763 patients, respectively, who had an ECG and echocardiographic diastolic function assessment within 14 days with no exclusion criteria. It was also tested in 55,248 patients with indeterminate diastolic function by echocardiography. The model was evaluated using the area under the curve (AUC) of the receiver operating characteristic curve, and its prognostic performance was compared to echocardiography. The AUC for detecting increased filling pressure was 0.911. The AUCs to identify diastolic dysfunction grades ≥1, ≥2, and 3 were 0.847, 0.911, and 0.943, respectively. During a median follow-up of 5.9 years, 20,223 (20.5%) died. Patients with increased filling pressure predicted by AI-ECG had higher mortality than those with normal filling pressure, after adjusting for age, sex, and comorbidities in the test group (hazard ratio (HR) 1.7, 95% CI 1.645-1.757) similar to echocardiography and in the indeterminate group (HR 1.34, 95% CI 1.298-1.383). An AI-enabled ECG identifies increased filling pressure and diastolic function grades with a good prognostic value similar to echocardiography. AI-ECG is a simple and promising tool to enhance the detection of diseases associated with diastolic dysfunction and increased diastolic filling pressure.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10770308PMC
http://dx.doi.org/10.1038/s41746-023-00993-7DOI Listing

Publication Analysis

Top Keywords

filling pressure
28
diastolic function
20
increased filling
16
diastolic dysfunction
12
diastolic
9
left ventricular
8
ventricular diastolic
8
dysfunction increased
8
ai-enabled ecg
8
filling
7

Similar Publications

Size-Effect Enriched Phase Diagram in -Type Skutterudite Superconductor IrSb.

Inorg Chem

January 2025

Beijing National Laboratory for Condensed Matter Physics, Institute of Physics, Chinese Academy of Sciences, Beijing 100190, China.

Pressurized IrX (X = P and As) stands out as the sole -type superconductors among dozens of filled-skutterudites that are primarily characterized by -type charge carriers. The emergence of superconductivity is proposed to be intimately related to the inharmonic rattling phonons originating from the filled atoms. Here, we explore the impact of the size effect of the rattling atoms by substituting X with Sb, whose radius is 30 and 17% larger than those of P and As, respectively.

View Article and Find Full Text PDF

The high compliance of the urinary bladder during filling is essential for its proper function, enabling it to accommodate significant volumetric increases with minimal rise in transmural pressure. This study aimed to elucidate the physical mechanisms underlying this phenomenon by analyzing the ex vivo filling process in rat from a fully voided state to complete distension, without preconditioning, using three complementary imaging modalities. High-resolution micro-CT at 10.

View Article and Find Full Text PDF

Hollow-core optical fiber (HCF) gas cells are an attractive option for many applications including metrology and non-linear optics due to the enhanced gas-light interaction length in a compact and lightweight format. Here, we report the first demonstration and characterization of a selectively pressurized, hermetically sealed hollow-core fiber-based gas cell, where the core is filled with a higher gas pressure than the cladding to enhance the optical performance. This differential gas pressure creates a gas-induced differential refractive index (GDRI) that is shown to enable significant modification of the HCF's optical performance.

View Article and Find Full Text PDF

High-order harmonics have been widely used as reliable tabletop coherent radiation sources recently, but their applications have often been limited by the available pulse energy. Here, we report that by using an overdriven intense laser in a long waveguide with high-pressure gas, phase matching can be achieved in three distinct "regimes". In the third regime, favorable phase matching is achieved at near-axis positions to enhance harmonic yields.

View Article and Find Full Text PDF

Background: Pressure injuries are costly and can lead to mortality and psychosocial consequences if not managed effectively. Proper management of pressure injuries is crucial for quality nursing care. However, there is limited research on nurses' knowledge and practices in preventing and managing pressure injuries among critically ill patients in Rwanda.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!