Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: More than 95% of cervical cancers and their precancerous lesions are caused by human papillomavirus (HPV). Cell-free (cf) HPV DNA detection in blood samples may serve as a monitoring tool for cervical cancer.
Methods: In our methodological study, an HPV panel for simultaneous detection of 24 types using mass spectrometry-based analysis was developed for liquid biopsy approaches and tested on HPV positive cell lines, plasmid controls, and cervical high-grade squamous intraepithelial lesions (HSIL) in positive smear samples (n = 52). It was validated in cfDNA blood samples (n = 40) of cervical cancer patients.
Results: The HPV panel showed proficient results in cell lines and viral plasmids with a limit of detection of 1 IU (international units)/µL for HPV16/18 and 10GE/µL for HPV11/31/33/39/45/51/52/58/59 and a specificity of 100% for the tested HPV types. In cervical smear samples, HPV DNA was detected with a sensitivity of 98.14%. The overall agreement between the new HPV panel and clinical records was 97.2% (κ = 0.84). In cervical cancer cfDNA, 26/40 (65.0%) tested positive for any HPV type, with most infections due to hrHPV (24/26). HPV positive samples were found in all FIGO stages, with the highest positivity ratio in FIGO III and IV. Even the lowest stage, FIGO I, had 12/23 (52.2%) patients with a positive HPV plasma status.
Conclusions: This proof-of-concept paper shows that the described assay produces reliable results for detecting HPV types in a multiplex mass spectrometry-based assay in cervical smear and cfDNA with high specificity and sensitivity in both cohorts. The assay shows potential for liquid biopsy-based applications in monitoring cervical cancer progression.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1093/clinchem/hvad182 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!