A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Measurement accuracy in silicon photonic ring resonator thermometers: identifying and mitigating intrinsic impairments. | LitMetric

Silicon photonic ring resonator thermometers have been shown to provide temperature measurements with a 10 mK accuracy. In this work we identify and quantify the intrinsic on-chip impairments that may limit further improvement in temperature measurement accuracy. The impairments arise from optically induced changes in the waveguide effective index, and from back-reflections and scattering at defects and interfaces inside the ring cavity and along the path between light source and detector. These impairments are characterized for 220 × 500 nm Si waveguide rings by experimental measurement in a calibrated temperature bath and by phenomenological models of ring response. At different optical power levels both positive and negative light induced resonance shifts are observed. For a ring with L = 100 µm cavity length, the self-heating induced resonance red shift can alter the temperature reading by 200 mK at 1 mW incident power, while a small blue shift is observed below 100 µW. The effect of self-heating is shown to be effectively suppressed by choosing longer ring cavities. Scattering and back-reflections often produce split and distorted resonance line shapes. Although these distortions can vary with resonance order, they are almost completely invariant with temperature for a given resonance and do not lead to measurement errors in themselves. The effect of line shape distortions can largely be mitigated by tracking only selected resonance orders with negligible shape distortion, and by measuring the resonance minimum wavelength directly, rather than attempting to fit the entire resonance line shape. The results demonstrate the temperature error due to these impairments can be limited to below the 3 mK level through appropriate design choices and measurement procedures.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.499055DOI Listing

Publication Analysis

Top Keywords

measurement accuracy
8
silicon photonic
8
photonic ring
8
ring resonator
8
resonator thermometers
8
resonance
8
induced resonance
8
ring
6
temperature
6
measurement
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!