A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Volume holographic illuminator for Airy light-sheet microscopy. | LitMetric

Airy light sheets combined with the deconvolution approach can provide multiple benefits, including large field of view (FOV), thin optical sectioning, and high axial resolution. The efficient design of an Airy light-sheet fluorescence microscope requires a compact illumination system. Here, we show that an Airy light sheet can be conveniently implemented in microscopy using a volume holographic grating (VHG). To verify the FOV and the axial resolution of the proposed VHG-based Airy light-sheet fluorescence microscope, ex-vivo fluorescently labeled Caenorhabditis elegans (C. elegans) embryos were imaged, and the Richardson-Lucy deconvolution method was used to improve the image contrast. Optimized parameters for deconvolution were compared with different methods. The experimental results show that the FOV and the axial resolution were 196 µm and 3 µm, respectively. The proposed method of using a compact VHG to replace the common spatial light modulator provides a direct solution to construct a compact light-sheet fluorescence microscope.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.507947DOI Listing

Publication Analysis

Top Keywords

airy light-sheet
12
axial resolution
12
light-sheet fluorescence
12
fluorescence microscope
12
volume holographic
8
airy light
8
fov axial
8
airy
5
holographic illuminator
4
illuminator airy
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!