AI Article Synopsis

  • The Cook® Airway Exchange Catheter (AEC) is a tool primarily used for replacing tracheal tubes but has a higher failure rate when switching from a single-lumen to a double-lumen tube.
  • A case report is presented involving a 58-year-old patient who faced unexpected difficulties during airway management when transitioning to a double-lumen tube after a surgical procedure.
  • The report illustrates a novel application of the Cook® AEC as a means to maintain ventilation and assist in intubation using a videolaryngoscope, emphasizing its utility in challenging airway situations despite potential failures during tube exchanges.

Article Abstract

BACKGROUND The Cook® Airway ExchangeCatheter (Cook® AEC, Cook Group Incorporated, Bloomington, Indiana, USA) is an 83-cm-long graduated hollow tube with an external diameter of 11, 14, or 19 French, commonly used for tracheal tube replacement. Although this application is reliable in the exchange of single-lumen tubes, the failure rate markedly rises during the exchange from a single-lumen to a double-lumen endotracheal tube. It is also often used as a bridge to extubation in patients with difficult airways and for oxygenation support applications. CASE REPORT We describe the case of a 58-year-old patient with unexpected difficult airway management. He was scheduled to undergo a minimally invasive hybrid esophagectomy (laparoscopic abdominal stage followed by an open right thoracotomy, requiring one-lung ventilation with a double-lumen tube). After the laparoscopic abdominal stage, performed with a single-lumen endotracheal tube, we exchanged it for a double-lumen endotracheal tube. After several unsuccessful exchanges with a Cook® Airway Exchange Catheter due to the flexibility of the exchange catheter, we decided to use the exchange catheter as a method to maintain adequate ventilation while using it as a target to facilitate tracheal intubation alongside it, using a videolaryngoscope. CONCLUSIONS This case report discusses an unusual use of the Cook® Airway ExchangeCatheter during videolaryngoscopic double-lumen endotracheal tube (DLT) intubation. It reviews previously documented uses in the literature, while highlighting the possibility of failure during tube exchange. It also highlights its value as a support for oxygenation and ventilation during difficult intubation attempts.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10775132PMC
http://dx.doi.org/10.12659/AJCR.942288DOI Listing

Publication Analysis

Top Keywords

cook® airway
16
exchange catheter
16
endotracheal tube
16
double-lumen endotracheal
12
tube
9
difficult airway
8
airway management
8
airway exchange
8
double-lumen tube
8
airway exchangecatheter
8

Similar Publications

Exposure to influenza A virus (IAV), respiratory syncytial virus (RSV), and human metapneumovirus (hMPV) is well-known to increase the risk of pneumonia in humans. Type I interferon (IFN-I) is a hallmark response to acute viral infections, and alveolar macrophages (AMs) constitute the first line of airway defense against opportunistic bacteria. Our study reveals that virus-induced IFN-I receptor (IFNAR1) signaling directly impairs AM-dependent antibacterial protection.

View Article and Find Full Text PDF

Rationale: Previous studies evaluating the effect of continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea (OSA) on blood pressure (BP) showed variable results. Moreover, several studies recruited patients with normal or controlled BP, and compliance to antihypertensive drugs was not monitored. In addition, very few studies investigated central BP in this scenario.

View Article and Find Full Text PDF

Objective: Although the efficacy of high-flow nasal oxygen therapy in delaying or avoiding intubation in patients with hypoxemic respiratory failure has been studied, its potential for facilitating early weaning from invasive mechanical ventilation remains unexplored.

Methods: In this randomized controlled trial, 80 adults with acute hypoxemic respiratory failure requiring invasive mechanical ventilation for > 48 hours were enrolled and divided into two groups: conventional weaning and early weaning via high-flow nasal oxygen. In the conventional weaning group, the spontaneous breathing trial was performed after the PaO2/FiO2 ratio was ≥ 200, whereas in the high-flow nasal oxygen group, the spontaneous breathing trial was conducted earlier when the PaO2/FiO2 ratio was 150 - 200.

View Article and Find Full Text PDF

Establishment of a Mouse Model with Cough Hypersensitivity via Inhalation of Citric Acid.

J Vis Exp

January 2025

State Key Laboratory of Respiratory Disease, The First Affiliated Hospital of Guangzhou Medical University, Guangzhou Medical University;

Cough is one of the most common symptoms of many respiratory diseases. Chronic cough significantly impacts quality of life and imposes a considerable economic burden. Increased cough sensitivity is a pathophysiological hallmark of chronic cough.

View Article and Find Full Text PDF

Purpose Of Review: We aim to summarize the available literature guiding tailored sedation practices for specific conditions encountered in the Cardiovascular Intensive Care Unit (CICU).

Recent Findings: Data specific for the CICU population is lacking. Preclinical data and observational studies guide sedation approaches for specific pathologies that we have used to generate a guideline for sedative choice for various scenarios.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!