Clinical outcomes of different types of metallic stents in malignant distal duodenum stenosis: A retrospective study.

J Formos Med Assoc

Division of Gastroenterology and Hepatology, Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan; Department of Internal Medicine, College of Medicine, National Taiwan University, Taipei, Taiwan. Electronic address:

Published: August 2024

Background/purpose: Endoscopic stenting at malignant distal duodenum stenosis (MDDS) is challenging because of the duodenal C-loop configuration, the acute angle of the duodenojejunal junction, and the limited length of the endoscope. Few studies have investigated the clinical outcomes of stenting at the distal duodenum. Therefore, this study aimed to investigate the clinical outcomes of treating MDDS with different types of metallic stents.

Methods: From January 2012 to December 2020, fifty-six patients with MDDS who underwent duodenal stenting were enrolled for analysis. Thirty-five patients received uncovered self-expandable metallic stents (UC-SEMS), and twenty-one patients received partially covered self-expandable metallic stents (PC-SEMS). All patients were followed up till death or for 18 months. The clinical success rate, stent dysfunction rate, and stent patency were compared between the groups. Multivariate analysis was conducted to identify factors related to stent dysfunction.

Results: The clinical success rates were 85.7 % in both the UC-SEMS and PC-SEMS groups. Stent dysfunction rates (UC-SEMS: 34.3 %, PC-SEMS: 38.1 %, p = 0.773) and the average stent patency (UC-SEMS: 117.2 days, PC-SEMS: 100.0 days, p = 0.576) were not statistically different between the groups. Multivariate analysis disclosed the age ≥65 years was significantly related to stent dysfunction (odds ratio: 4.78, p = 0.031).

Conclusion: Both UC-SEMS and PC-SEMS are safe and effective treatment options for MDDS. However, stent dysfunction remains a significant issue to overcome, particularly in the elderly. Further research is needed to explore novel strategies that can improve the effectiveness of stent placement and reduce the risk of stent dysfunction.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jfma.2023.12.013DOI Listing

Publication Analysis

Top Keywords

stent dysfunction
20
clinical outcomes
12
metallic stents
12
distal duodenum
12
stent
9
types metallic
8
malignant distal
8
duodenum stenosis
8
patients received
8
self-expandable metallic
8

Similar Publications

MAFLD as a predictor of adverse cardiovascular events among CHD patients with LDL-C<1.8 mmol/L.

Nutr Metab Cardiovasc Dis

November 2024

Department of Cardiology and Institute of Vascular Medicine, Peking University Third Hospital, Beijing, China; Key Laboratory of Molecular Cardiovascular Science, Ministry of Education, Beijing, China. Electronic address:

Background And Aims: Patients receiving statin therapy still suffer from adverse cardiovascular events. Metabolic (dysfunction)-associated fatty liver disease (MAFLD) is a newly proposed concept that shares common metabolic risk factors with cardiovascular disease. This study aimed to investigate the association between MAFLD and adverse cardiovascular outcomes in coronary heart disease (CHD) patients with LDL-C<1.

View Article and Find Full Text PDF

Complete expiratory central airway collapse at general anesthesia recovery: a case report.

J Int Med Res

January 2025

Department of Anesthesiology, Sir Run Run Shaw Hospital, School of Medicine, Zhejiang University, Hangzhou, Zhejiang, China.

Expiratory central airway collapse is a degenerative tracheobronchial disease that is often overlooked because of its nonspecific clinical features. A man was admitted for evaluation of tracheal nodules. Following bronchoscopic biopsy, a significant increase in airway pressure occurred during anesthesia recovery.

View Article and Find Full Text PDF

Aneurysm dome and vessel pressure measurements with coiling, stent assisted coiling and flow diversion.

Acta Neurochir (Wien)

January 2025

Division of Neurosurgery, Beth Israel Deaconess Medical Center, Harvard Medical School, 110 Francis Street , Boston, MA, 02215, USA.

Background: Variability in long-term endovascular treatment outcomes for intracranial aneurysms has prompted questions regarding the effects of these treatments on aneurysm hemodynamics. Endovascular techniques disrupt aneurysmal blood flow and shear, but their influence on intra-aneurysmal pressure remains unclear. A better understanding of aneurysm pressure effects may aid in predicting outcomes and guiding treatment decisions.

View Article and Find Full Text PDF

: ST-segment elevation myocardial infarction (STEMI) remains a leading cause of mortality worldwide, primarily caused by acute thrombosis over atherosclerotic plaques. Simultaneous acute thrombosis in two coronary arteries is an exceptionally rare event. This report highlights a unique case of STEMI associated with cardiogenic shock due to dual coronary artery thrombosis and provides insights from a literature review on this rare condition.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!