3-D Contrast-Enhanced Fusion Ultrasound for Accurate Volume Assessment of Vessel Lumen and Plaque in Carotid Artery Disease as Compared With Computed Tomography Angiography.

Ultrasound Med Biol

Department of Vascular Surgery, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.

Published: March 2024

Objective: Three-dimensional contrast-enhanced fusion ultrasound (CEFUS) of atherosclerotic carotid arteries provides spatial visualization of the vessel lumen, creating a lumenography. As in 3-D computed tomography angiography (CTA), 3-D CEFUS outlines the contrast-filled lumen. Plaque and vessel contours are distinguished in 3-D CEFUS, allowing plaque volume quantification as a valid estimate of carotid plaque burden. Three-dimensional CEFUS is unproven in intermodality studies, vindicating the assessment of 3-D CEFUS applicability and comparing 3-D CEFUS and 3-D CTA lumenography as a proof-of-concept study.

Methods: Using an ultrasound system with magnetic tracking, a linear array transducer and SonoVue contrast agent, 3-D CEFUS acquisitions were generated by spatial stitching of serial 2-D images. From 3-D CEFUS and 3-D CTA imaging, the atherosclerotic carotid arteries were reconstructed with lumenography in an offline software program for lumen and plaque volume quantification. Bland-Altman analysis was used for inter-image modality agreement.

Results: The study included 39 carotid arteries. Mean lumen and plaque volume in 3-D CEFUS were 0.63 cm (standard deviation [SD]: 0.26) and 0.62 cm (SD: 0.26), respectively. Lumen volume differences between 3-D CEFUS and 3-D CTA were non-significant, with a mean difference of 0.01 cm (SD: 0.02, p = 0.26) and limits of agreement (LoA) range of ±0.11 cm. Mean plaque volume difference was -0.12 cm (SD: 0.19, p = 0.006) with a LoA range of ±0.39 cm.

Conclusion: There was strong agreement in lumenography between 3-D CEFUS and 3-D CTA. The interimage modality difference in plaque volumes was substantial because of challenging vessel wall definition in 3-D CTA. Three-dimensional CEFUS is viable in quantifying carotid plaque volume burden and can potentially monitor plaque development over time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2023.11.013DOI Listing

Publication Analysis

Top Keywords

3-d cefus
36
plaque volume
20
3-d cta
20
3-d
16
lumen plaque
16
cefus 3-d
16
cefus
12
carotid arteries
12
plaque
10
contrast-enhanced fusion
8

Similar Publications

3-D Contrast-Enhanced Fusion Ultrasound for Accurate Volume Assessment of Vessel Lumen and Plaque in Carotid Artery Disease as Compared With Computed Tomography Angiography.

Ultrasound Med Biol

March 2024

Department of Vascular Surgery, Copenhagen University Hospital, Rigshospitalet, Copenhagen, Denmark; Department of Clinical Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Denmark.

Objective: Three-dimensional contrast-enhanced fusion ultrasound (CEFUS) of atherosclerotic carotid arteries provides spatial visualization of the vessel lumen, creating a lumenography. As in 3-D computed tomography angiography (CTA), 3-D CEFUS outlines the contrast-filled lumen. Plaque and vessel contours are distinguished in 3-D CEFUS, allowing plaque volume quantification as a valid estimate of carotid plaque burden.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!