Significance: A Fabry-Perot (FP) polymer film sensor can be used to detect acoustic waves in a photoacoustic endoscope (PAE) if the dimensions can be adequately scaled down in size. Current FP sensors have limitations in size, sensitivity, and array configurability.

Aim: We aim to characterize and demonstrate the imaging performance of a miniature FP sensor to evaluate the effects of reduced size and finite dimensions.

Approach: A transfer matrix model was developed to characterize the frequency response of a multilayer miniature FP sensor. An analytical model was derived to describe the effects of a substrate with finite thickness. Finite-element analysis was performed to characterize the temporal response of a sensor with finite dimensions. Miniature FP sensors were designed and fabricated using gold films as reflective mirrors on either side of a parylene C film deposited on a glass wafer. A single-wavelength laser was used to interrogate the sensor using illumination delivered by fiber subprobes. Imaging phantoms were used to verify FP sensor performance, and images of blood vessels were collected from a live mouse.

Results: The finite thickness substrate of the FP sensor resulted in echoes in the time domain signal that could be removed by back filtering. The substrate acted as a filter in the frequency domain. The finite lateral sensor dimensions produced side waves that could be eliminated by surface averaging using an interrogation beam with adequate diameter. The fabricated FP sensor produced a noise-equivalent pressure = 0.76 kPa, bandwidth of 16.6 MHz, a spectral full-width at-half-maximum = 0.2886 nm, and quality factor . Photoacoustic images were collected from phantoms and blood vessels in a live mouse.

Conclusions: A miniature wafer-based FP sensor design has been demonstrated with scaled down form factor for future use in PAE.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10760494PMC
http://dx.doi.org/10.1117/1.JBO.29.S1.S11514DOI Listing

Publication Analysis

Top Keywords

sensor
11
fabry-perot polymer
8
polymer film
8
miniature sensor
8
finite thickness
8
blood vessels
8
finite
5
scaling dimensions
4
dimensions fabry-perot
4
film acoustic
4

Similar Publications

Background: Attention-deficit/hyperactivity disorder (ADHD) is a common neuro-developmental disorder that often persists into adulthood. Moreover, it is frequently accompanied by bipolar disorder (BD) as well as borderline personality disorder (BPD). It is unclear whether these disorders share underlying pathomechanisms, given that all three are characterized by alterations in affective states, either long or short-term.

View Article and Find Full Text PDF

Patients with cirrhosis have high systemic inflammation (TNFα, CRP, and IL-6) that is associated with poor outcomes. These biomarkers need continuous non-invasive monitoring, which is difficult with blood. We studied the AWARE sweat-sensor to measure these in passively expressed sweat in healthy people (N = 12) and cirrhosis (N = 32, 10 outpatients/22 inpatients) for 3 days.

View Article and Find Full Text PDF

This study proposes a novel, highly sensitive neutron detector design utilizing a unique multi-layered configuration. Each layer consists of a LiF: ZnS(Ag) scintillator coupled with a transparent neutron moderator that also functions as a light guide for the Silicon Photomultiplier (SiPM) light sensor. This design offers a cost-effective and readily available alternative for existing neutron detectors.

View Article and Find Full Text PDF

Energy efficiency plays a major role in sustaining lifespan and stability of the network, being one of most critical factors in wireless sensor networks (WSNs). To overcome the problem of energy depletion in WSN, this paper proposes a new Energy Efficient Clustering Scheme named African Vulture Optimization Algorithm based EECS (AVOACS) using AVOA. The proposed AVOACS method improves clustering by including four critical terms: communication mode decider, distance of sink and nodes, residual energy and intra-cluster distance.

View Article and Find Full Text PDF

A thermochromic pigment, derived from reaction of ethylenediamine and rhodamine B known as MA-RB, has been successfully developed. This pigment showcases temperature-controlled visible color-transformation properties in both solid and solution states. The thermochromic pigment MA-RB exhibits a notable color change from light pink to rose red, triggered by thermal excitation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!