A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ratiometric fluorescence-based and chromogenic sensors for the detection of fluoride ions and their application in real samples. | LitMetric

This review focuses on the results of synthetic ratiometric fluorescent and colorimetric probes, which have been applied to qualitatively and quantitatively detect fluoride anions in cells, living organisms, and real samples. Primary attention is given to progress made in the working mechanism and applications of these probes to detect fluoride ions in living systems. In addition, design strategies and detection limit for these probes are discussed. This review aims to deliver a comprehensive compilation of the examples reported from 2005 to 2021 on the developments of ratiometric chromogenic and fluorogenic chemosensors for fluoride anions. A total of 20 different ratiometric/colorimetric sensors have been selected for the novelty in their design, sensitivity, detection limit, dynamic range, and speed of detection based on the three fundamental principles of F ion detection, namely Si-O bond cleavage; excimer emission; and intramolecular charge transfer emission through the B-F monomer, B-F-B bridged dimers, and deprotonation of the amide N-H. Special emphasis has been given to categorize the fluorophores that work in aqueous media, and possible strategies that might be adopted to design green sensors are discussed. Finally, a tabular summary of the comparative studies of all the sensors based on their sensitivity, detection limit, working solvent, and applications is provided. This extensive review may expedite improvements in the development of advanced fluorescent probes for vast and stimulating applications in the future.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3ay01840gDOI Listing

Publication Analysis

Top Keywords

detection limit
12
fluoride ions
8
real samples
8
detect fluoride
8
fluoride anions
8
sensitivity detection
8
detection
6
ratiometric fluorescence-based
4
fluorescence-based chromogenic
4
sensors
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!