The Choroid Plexus as an Alternative Locus for the Identification of the Arterial Input Function for Calculating Cerebral Perfusion Metrics Using MRI.

AJNR Am J Neuroradiol

From the Joint Department of Medical Imaging and the Functional Neuroimaging Lab (O.S., E.S.S., J.P., J.D., A.P., J.A.F., D.J.M.), University Health Network, Toronto, Ontario, Canada.

Published: December 2023

Background And Purpose: MR imaging-based cerebral perfusion metrics can be obtained by tracing the passage of a bolus of contrast through the microvasculature of the brain parenchyma. Thus, the temporal signal pattern of the contrast agent is typically measured over a large artery such as the MCA to generate the arterial input function. The largest intracranial arteries in the brain may not always be suitable for selecting the arterial input function due to skull base susceptibility artifacts or reduced size from steno-occlusive disease. Therefore, a suitable alternative arterial input function window would be useful. The choroid plexus is a highly vascular tissue composed essentially of arterialized blood vessels and acellular stroma with low metabolic requirements relative to its blood flow and may be a suitable alternative to identify the arterial input function.

Materials And Methods: We studied 8 healthy participants and 7 patients with gliomas who were administered a bolus of gadolinium. We selected an arterial input function from both the left and right M1 segments of the MCA and both lateral ventricles of the choroid plexus for each participant. We compared the changes in the T2* signal and the calculated resting perfusion metrics using the arterial input functions selected from the MCA and choroid plexus.

Results: We found no systematic difference between resting perfusion metrics in GM and WM when calculated using an arterial input function from the MCA or choroid plexus in the same participant.

Conclusions: The choroid plexus provides an alternative location from which an arterial input function may be sampled when a suitable measure over an MCA is not available.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10756570PMC
http://dx.doi.org/10.3174/ajnr.A8099DOI Listing

Publication Analysis

Top Keywords

arterial input
36
input function
28
choroid plexus
20
perfusion metrics
16
arterial
9
input
9
plexus alternative
8
cerebral perfusion
8
suitable alternative
8
resting perfusion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!