A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Fluocinolone Acetonide Loaded Chitosan Nanofiber Scaffolds for Treatment of Ocular Disorders: Characterization, Corneal and Scleral Evaluation. | LitMetric

Fluocinolone Acetonide Loaded Chitosan Nanofiber Scaffolds for Treatment of Ocular Disorders: Characterization, Corneal and Scleral Evaluation.

Curr Eye Res

Department of Pharmaceutics, SVKM's Dr. Bhanuben Nanavati College of Pharmacy, University of Mumbai, Maharashtra, India.

Published: May 2024

Purpose: Drugs administered in the ocular region need to overcome ocular barriers without permanently damaging the ocular tissues. Moreover, ocular disorders of the posterior segment are more difficult to treat due to invasive procedures required to reach the posterior segment. Hence, to treat posterior disorders of the eye an attempt was made to develop nanofiber (NF) scaffolds for effective management of chronic posterior uveitis. Nanofibers (NFs) were formulated using the electrospinning technique.

Methods: NF scaffolds were formulated using the electrospinning technique. The effect of different concentrations of chitosan on NF production was studied by considering different ratios of chitosan (CS) and polyvinyl alcohol (PVA). Physicochemical characterization of NFs was performed to evaluate developed NFs.

Results: The optimized NF scaffold had a diameter of 129 ± 3 nm. NF scaffolds were found to have a tensile strength of 0.2882 ± 0.078 N/m, thickness of 0.16 ± 0.05 mm, and drug entrapment of 95 ± 2.0%. The bioadhesive strength of the NF was found to be 257.3 ± 0.04 g/cm indicating high bioadhesion of NFs to the ocular tissues. The in-vitro, ex-vivo corneal and ex-vivo scleral drug release after 12 h was found to be 78.4 ± 1.0%, 65.33 ± 0.2% and 78.41 ± 1.0%, respectively. Ex-vivo whole eye model experiment indicated a concentration of about 40 ± 1.75% of drug permeated from corneal layer to the vitreous humor after 12 h. The Hen's egg test-chorioallantoic membrane study (HET-CAM) study and in-vitro cytotoxicity study on Statens Seruminstitut Rabbit Cornea (SIRC) cell lines indicated that the developed drug-loaded NF scaffolds were found to be non-toxic as compared to pure drug, thus suggesting cytocompatibility.

Conclusion: Results of HET-CAM, sterility and ex-vivo studies indicate that the developed formulation is non-toxic, sterile, and effective for the ocular delivery of fluocinolone acetonide to the posterior segment of eye.

Download full-text PDF

Source
http://dx.doi.org/10.1080/02713683.2023.2298917DOI Listing

Publication Analysis

Top Keywords

posterior segment
12
fluocinolone acetonide
8
nanofiber scaffolds
8
ocular disorders
8
ocular tissues
8
formulated electrospinning
8
ocular
7
scaffolds
5
posterior
5
acetonide loaded
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!