In this work, a multifunctional preservative film of ZnO/carboxymethyl starch/chitosan (ZnO/CMS/CS) with the unique "Steel Wire Mesh" structure is fabricated by the chemical crosslinked of ZnO NPs, CMS and CS. Unlike traditional nano-filled polymer film, the formation of the "Steel Wire Mesh" structure of ZnO/CMS/CS film is based on the synergistic effect of ZnO NPs filled CMS/CS and the coordination crosslinked between CMS/CS and Zn derived from ZnO NPs. Thanks to the "Steel Wire Mesh" structure, the tensile strength and water vapor barrier of 2.5ZnO/10CMS/CS film are 2.47 and 1.73 times than that of CS film, respectively. Furthermore, the transmittance of 2.5ZnO/10CMS/CS film during antifogging test is close to 89 %, confirming its excellent antifogging effects. And the 2.5ZnO/10CMS/CS film also exhibits excellent long-acting antibacterial activity (up to 202 h), so it can maintain the freshness and appearance of strawberries at least 5 days. More importantly, the 2.5ZnO/10CMS/CS film is sensitive to humidity changes, which achieves real-time humidity monitoring of the fruit storage environment. Note that the preparation method of the film is safe, simple and environmentally friendly, and its excellent degradation performance will not bring any problems of food safety and environmental pollution.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijbiomac.2023.129090DOI Listing

Publication Analysis

Top Keywords

"steel wire
16
wire mesh"
16
mesh" structure
16
25zno/10cms/cs film
16
zno nps
12
film
10
zno/carboxymethyl starch/chitosan
8
unique "steel
8
high-strength antifogging
4
antifogging antibacterial
4

Similar Publications

Proper alignment of the teeth not only aids in functional occlusion but also promotes harmonious gingival contours, potentially reducing the risk of inflammation and gingival recession. This case series aimed to evaluate the effectiveness of optimizing axial inclination through clear aligner orthodontic treatment in addressing gingival recession defects. This case series included nine patients, aged 20-36 years, who presented with varying degrees of gingival recession on 12 mandibular incisors.

View Article and Find Full Text PDF

Objective: The endoscopic transsphenoidal approach is commonly used for sellar and suprasellar pathologies. However, reaching above the diaphragma sella, especially for posterosuperior and retrocavernous orientation, still poses some challenges. We designed and developed a steerable tip suction cannula (STSC) that has distinct leverage for endoscopic resection of such pathologies.

View Article and Find Full Text PDF

Assessment of Surface Integrity in Precision Electrical Discharge Machining of HSS EN HS6-5-2C.

Micromachines (Basel)

December 2024

Department of Process Engineering, Faculty of Manufacturing Technologies with the Seat in Presov, Technical University of Kosice, Sturova 31, 080 01 Presov, Slovakia.

The integrity of the machined surface in precision wire electrical discharge machining (WEDM) of electrically conductive materials is one of the most important quality indicators. The integrity parameters of the machined surface are primarily monitored in terms of micro and macro geometry parameters. This paper presents the results obtained as a part of experimental research aimed at evaluating surface crack density (SCD) when machining EN HS6-5-2C using WEDM technology.

View Article and Find Full Text PDF

Narrow-gap arc welding is an efficient method that significantly enhances industrial production efficiency and reduces costs. This study investigates the application of low-alloy steel wire EG70-G in narrow-gap gas metal arc welding (GMAW) on thick plates. Experimental observations were made to examine the arc behavior, droplet transition behavior, and weld formation characteristics of double-wire welding under various process parameters.

View Article and Find Full Text PDF

Background: Proper torque control is crucial to the outcome of orthodontic treatment. This study aimed to employ finite element analysis to compare the torque capabilities of a novel spherical self-ligating bracket with a lock-hook system against those of commonly used passive self-ligating and conventional bracket systems, as well as to reveal the biomechanical changes in the periodontal ligament (PDL) during torque expression.

Methods: A maxillary right central incisor, along with its PDL and alveolar bone, were modeled.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!