The meniscal tissue is a layered material with varying properties influenced by collagen content and arrangement. Understanding the relationship between structure and properties is crucial for disease management, treatment development, and biomaterial design. The internal layer of the meniscus is softer and more deformable than the outer layers, thanks to interconnected collagen channels that guide fluid flow. To investigate these relationships, we propose an integrated approach that combines Computational Fluid Dynamics (CFD) with Image Analysis (CFD-IA). We analyze fluid flow in the internal architecture of the human meniscus across a range of inlet velocities (0.1 mm/s to 1.6 m/s) using high-resolution 3D micro-computed tomography scans. Statistical correlations are observed between architectural parameters (tortuosity, connectivity, porosity, pore size) and fluid flow parameters (Re number distribution, permeability). Some channels exhibit Re values of 1400 at an inlet velocity of 1.6 m/s, and a transition from Darcy's regime to a non-Darcian regime occurs around an inlet velocity of 0.02 m/s. Location-dependent permeability ranges from 20-32 Darcy. Regression modelling reveals a strong correlation between fluid velocity and tortuosity at high inlet velocities, as well as with channel diameter at low inlet velocities. At higher inlet velocities, flow paths deviate more from the preferential direction, resulting in a decrease in the concentration parameter by an average of 0.4. This research provides valuable insights into the fluid flow behaviour within the meniscus and its structural influences. 3D models and image stack are available to download at https://doi.org/10.5281/zenodo.10401592. STATEMENT OF SIGNIFICANCE: The meniscus is a highly porous soft tissue with remarkable properties of load transfer and energy absorption. We give insight on the mechanism of energy absorption from high resolution uCT scans, never presented before, and a new method which combine CFD and image. The structure is similar to a sandwich structure with a stiff outside layer and a soft internal layer made of collagen channels oriented in a preferential direction guiding the fluid flow, enabling it to accommodate deformation and dissipate energy, making it a potentially optimized damping system. We investigate architectural/ fluid flow parameters- fluid regimes relationship, which is of interest of the readers working on designing suitable biomimetic systems that can be adopted for replacement.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.actbio.2023.12.042 | DOI Listing |
Int Endod J
January 2025
School of Medicine and Dentistry, Griffith University, Gold Coast, Australia.
Introduction: Biofilms may show varying adherence strengths to dentine. This study quantified the shear force required for the detachment of multispecies biofilm from the dentine using fluid dynamic gauging (FDG) and computation fluid dynamics (CFD). To date this force has not been quantified.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Mechanical Engineering, Yazd University, Yazd, Iran.
In this research, the impact of differing densities and viscosities of two dissolving fluids on their mixing efficiency, as well as the effects of various excitation frequencies on the performance of the mixer, have been examined. For this purpose, a two-dimensional microchannel equipped with an oscillating circular cylinder was used, operating within a Strouhal number range of 0.1-0.
View Article and Find Full Text PDFFluids Barriers CNS
January 2025
Adelaide Spinal Research Group & Centre for Orthopaedics and Trauma Research, Faculty of Health and Medical Sciences, The University of Adelaide, Level 7, Adelaide Health and Medical Sciences Building, North Terrace, Adelaide, SA, 5005, Australia.
Background: Traumatic spinal cord injury (SCI) causes spinal cord swelling and occlusion of the subarachnoid space (SAS). SAS occlusion can change pulsatile cerebrospinal fluid (CSF) dynamics, which could have acute clinical management implications. This study aimed to characterise SAS occlusion and investigate CSF dynamics over 14 days post-SCI in the pig.
View Article and Find Full Text PDFSci Rep
January 2025
Department of Neurosurgery, Kepler University Hospital and Johannes Kepler University Linz, Wagner-Jauregg Weg 15, 4020 Linz and Altenbergerstrasse 69, Linz, 4040, Austria.
Accurate rupture risk assessment is essential for optimizing treatment decisions in patients with cerebral aneurysms. While computational fluid dynamics (CFD) has provided critical insights into aneurysmal hemodynamics, most analyses focus on blood flow patterns, neglecting the biomechanical properties of the aneurysm wall. To address this limitation, we applied Fluid-Structure Interaction (FSI) analysis, an integrative approach that simulates the dynamic interplay between hemodynamics and wall mechanics, offering a more comprehensive risk assessment.
View Article and Find Full Text PDFNeuron
January 2025
Division of Glial Disease and Therapeutics, Center for Translational Neuromedicine, University of Copenhagen, Copenhagen, Denmark; Center for Translational Neuromedicine, University of Rochester Medical Center, Rochester, NY, USA. Electronic address:
Continuous sleep restores the brain and body, whereas fragmented sleep harms cognition and health. Microarousals (MAs), brief (3- to 15-s-long) wake intrusions into sleep, are clinical markers for various sleep disorders. Recent rodent studies show that MAs during healthy non-rapid eye movement (NREM) sleep are driven by infraslow fluctuations of noradrenaline (NA) in coordination with electrophysiological rhythms, vasomotor activity, cerebral blood volume, and glymphatic flow.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!