A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrastructural insights from myocardial ablation lesions from microsecond pulsed field vs radiofrequency energy. | LitMetric

Background: Ultrastructural findings immediately after pulsed field ablation (PFA) of the myocardium have not been described.

Objectives: The purpose of this study was to elucidate ultrastructural characteristics and differences between microsecond PFA at the 1- and 4-hour timepoints after pulse delivery and to compare them to irrigated radiofrequency ablation (RFA) lesions.

Methods: Healthy swine underwent endocardial PFA or RFA followed by necropsy. Discrete microsecond PFA and irrigated RFA lesions were created in the ventricles with a lattice tip ablation catheter. Lesions were delivered in a manner so as to allow sampling to occur 1 and 4 hours after ablation. All lesions were located at necropsy, and samples were carefully obtained from within the lesion core, lesion periphery, and adjacent healthy myocardium. Transmission electron microscopic assessment was performed after fixation using paraformaldehyde and glutaraldehyde.

Results: One hour after microsecond PFA delivery, myocytes were noted to be significantly and uniformly disrupted. Clustered, misaligned, swollen mitochondria coupled with degenerating nuclei and condensed chromatin were visualized. These findings progressed over the subsequent few hours with worsening edema. Similar changes were seen with RFA but reduced in severity. However, there was prominent extravasation of red blood cells with occlusion of capillaries that was not seen in PFA. At the lesion periphery, an abrupt change in the degree of myocyte damage was observed with PFA but not RFA.

Conclusion: Transmission electron microscopy demonstrates evidence of widespread destruction of myocytes as early as an hour after PFA and corroborates known histologic features such as sparing of vessels and sharp lesion margins.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.hrthm.2023.12.017DOI Listing

Publication Analysis

Top Keywords

microsecond pfa
12
ablation lesions
8
pulsed field
8
pfa
8
lesion periphery
8
transmission electron
8
ablation
5
ultrastructural insights
4
insights myocardial
4
myocardial ablation
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!