The surgical technique and the intraoperative technology that support spinal pedicle screw placement have consistently evolved over the past decades to decrease the misplacement rate of pedicle screws. We retrospectively evaluated our case series by analyzing the period 2016-2020. Patients undergoing pedicle screw fixation for cervical, thoracic, or lumbar spine degenerative diseases have been included. Surgery was carried out with the aid of intraoperative 3D C-arm fluoroscopy to assess and optimize screw placement and/or correct possible mispositioning. Each patient underwent a postoperative CT scan. Our aim was to evaluate the safety and accuracy of pedicle screw placement and estimate the variation in mispositioning rates. We carried out 329 surgical procedures, as follows: 70 cervical, 78 thoracic spine, and 181 lumbar spine surgeries. An excellent overall pedicle screw positioning was obtained, with slight differences between the cervical (98.6%), thoracic (100%), and lumbar (98.9%) tracts. Accordingly, only three patients required a revision surgery owing to mispositioning (0.91%). In particular, intraoperative C-arm fluoroscopy significatively improved the accuracy of thoracic screw positioning, as shown by postoperative CT scans. Our experience proves the crucial role of intraoperative C-arm fluoroscopy in pursuing optimal technical results and improving patient outcomes at follow-up.