A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A workflow for predicting radiofrequency-induced heating around bilateral deep brain stimulation electrodes in MRI. | LitMetric

Background: Heating around deep brain stimulation (DBS) in magnetic resonance imaging (MRI) occurs when the time-varying electromagnetic (EM) fields induce currents in the electrodes which can generate heat and potentially cause tissue damage. Predicting the heating around the electrode contacts is important to ensure the safety of patients with DBS implants undergoing an MRI scan. We previously proposed a workflow to predict heating around DBS contacts and introduced a parameter, equivalent transimpedance, that is independent of electrode trajectories, termination, and radiofrequency (RF) excitations. The workflow performance was validated in a unilateral DBS system.

Purpose: To predict RF heating around the contacts of bilateral (DBS) electrodes during an MRI scan in an anthropomorphic head phantom.

Methods: Bilateral electrodes were fixed in a skull phantom filled with hydroxyethyl cellulose (HEC) gel. The electrode shafts were suspended extracranially, in a head and torso phantom filled with the same gel material. The current induced on the electrode shaft was experimentally measured using an MR-based technique 3 cm above the tip. A transimpedance value determined in a previous offline calibration was used to scale the shaft current and calculate the contact voltage. The voltage was assigned as a boundary condition on the electrical contacts of the electrode in a quasi-static (EM) simulation. The resulting specific absorption rate (SAR) distribution became the input for a transient thermal simulation and was used to predict the heating around the contacts. RF heating experiments were performed for eight different lead trajectories using circularly polarized (CP) excitation and two linear excitations for one trajectory. The measured temperatures for all experiments were compared with the simulated temperatures and the root-mean-squared errors (RMSE) were calculated.

Results: The RF heating around the contacts of both bilateral electrodes was predicted with ≤ 0.29°C of RMSE for 20 heating scenarios.

Conclusion: The workflow successfully predicted the heating for different bilateral DBS trajectories and excitation patterns in an anthropomorphic head phantom.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10922480PMC
http://dx.doi.org/10.1002/mp.16913DOI Listing

Publication Analysis

Top Keywords

predict heating
12
heating contacts
12
heating
10
heating bilateral
8
deep brain
8
brain stimulation
8
electrodes mri
8
mri scan
8
contacts bilateral
8
bilateral dbs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!