A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Two-year real world clinical outcomes after intravascular imaging device guided percutaneous coronary intervention with ultrathin-strut biodegradable-polymer sirolimus-eluting stent. | LitMetric

Background: There are little clinical data on imaging-guided percutaneous coronary intervention (PCI) 1 year after the biodegradable-polymer sirolimus-eluting stents (BP-SES) implantation, when the polymer disappears.

Methods: We retrospectively analyzed 2455 patients who underwent successful PCI with BP-SES or durable-polymer everolimus-eluting stents (DP-EES) between September 2011 and March 2021, and compared 2-year clinical outcomes of BP-SES (n = 459) with DP-EES (n = 1996). The outcome measures were target lesion revascularization (TLR) and major adverse cardiac events (MACE), defined as a composite of cardiac death, myocardial infarction, target vessel revascularization, and stent thrombosis. Multivariate analysis using the Cox proportional hazard model and inverse probability weighting (IPW) analysis based on the propensity score were used to evaluate the clinical outcomes.

Results: The 2-year cumulative incidences of TLR (BP-SES: 4.9% vs. DP-SES: 6.1%, p = 0.304) and MACE (10.3% vs. 12.5%, p = 0.159) were similar between the two groups. Multivariable and IPW analysis revealed the risks of TLR (p = 0.388 and p = 0.500) and MACE (p = 0.139 and p = 0.083) also had no significant difference. There was a significant interaction between none/mild and moderate/severe calcification with respect to MACE and TLR (adjusted p for interaction = 0.036 and 0.047, respectively). The risk of MACE was significantly lower in BP-SES than in DP-EES in lesions with none/mild calcification (adjusted hazard ratio [aHR]: 0.53; 95% confidence interval [CI]: 0.30-0.91), while it was similar in those with moderate/severe calcification (aHR: 0.95; 95% CI: 0.58-1.55).

Conclusions: Compared with DP-EES, BP-SES demonstrated durable 2-year clinical outcomes. However, BP-SES showed better clinical performance than DP-EES for lesions with none/mild calcification.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ijcard.2023.131686DOI Listing

Publication Analysis

Top Keywords

clinical outcomes
12
percutaneous coronary
8
coronary intervention
8
biodegradable-polymer sirolimus-eluting
8
2-year clinical
8
outcomes bp-ses
8
ipw analysis
8
moderate/severe calcification
8
dp-ees lesions
8
lesions none/mild
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!