Background: Electrotactile systems are compact interfaces that can be used to convey information through the skin by producing a range of haptic sensations. In many applications, however, the user needs to perceive and interpret haptic stimulation while being engaged in parallel activities. Developing methods that ensure reliable recognition of electrotactile messages despite additional cognitive load is, therefore, an important step for the practical application of electrotactile displays.

Methods: This study investigated if a simple strategy of repeating electrotactile messages can improve message identification during multitasking. Ten participants identified 36 spatiotemporal electrotactile messages delivered through a 3 × 2 pad-matrix electrode placed on the torso while performing a concomitant cognitive task in three conditions: the messages were presented once (No-REP), and each message was repeated three (REP3) and five (REP5) times. The main outcome measure was the success rate (SR) of message identification.

Results: During multitasking, in the No-REP condition, the SR (median (IQR)) dropped to 56.25% (22.62%), demonstrating that the cognitive task decreased performance. However, the SR significantly improved with message repetitions, reaching 72.92% (21.87%) and 81.25% (18.66%) in REP3 and REP5 conditions respectively, without a statistically significant difference between REP3 and REP5.

Conclusions: Multitasking affected the efficacy of haptic communication, but message repetition was shown to be an effective strategy for improving performance. Additionally, only three repetitions were enough, as an additional increase in the duration of message transmission (5 repetitions) did not lead to further improvement. This study is an important step toward delivering electrotactile communication that can cope with the demands of real-world applications.

Download full-text PDF

Source
http://dx.doi.org/10.1111/aor.14700DOI Listing

Publication Analysis

Top Keywords

electrotactile messages
12
electrotactile communication
8
cognitive load
8
cognitive task
8
rep3 rep5
8
electrotactile
6
message
6
improving electrotactile
4
communication multi-pad
4
multi-pad electrode
4

Similar Publications

Improving electrotactile communication with a multi-pad electrode under cognitive load.

Artif Organs

June 2024

Neurorehabilitation Systems, Department of Health Science and Technology, Aalborg University, Aalborg, Denmark.

Background: Electrotactile systems are compact interfaces that can be used to convey information through the skin by producing a range of haptic sensations. In many applications, however, the user needs to perceive and interpret haptic stimulation while being engaged in parallel activities. Developing methods that ensure reliable recognition of electrotactile messages despite additional cognitive load is, therefore, an important step for the practical application of electrotactile displays.

View Article and Find Full Text PDF

Electrotactile stimulation is a technology that reproducibly elicits tactile sensations and can be used as an alternative channel to communicate information to the user. The presented work is a part of an effort to develop this technology into an unobtrusive communication tool for first responders. In this study, the aim was to compare the success rate (SR) between discriminating stimulation at six spatial locations (static encoding) and recognizing six spatio-temporal patterns where pads are activated sequentially in a predetermined order (dynamic encoding).

View Article and Find Full Text PDF

Encoding of spatial patterns using electrotactile stimulation via a multi-pad electrode placed on the torso.

Artif Organs

October 2022

Neurorehabilitation Systems, Department of Health Science and Technology, Faculty of Medicine, Aalborg University, Aalborg, Denmark.

Article Synopsis
  • Tactile stimulation can effectively convey information through spatial patterns, which helps avoid overwhelming other senses.
  • Various encoding schemes (simultaneous and sequential pad activation) were tested to determine the best method for identifying these patterns.
  • Results showed that sequential activation significantly improved pattern recognition rates, particularly with the SEQ-all method, which could be sped up without sacrificing accuracy.
View Article and Find Full Text PDF

Electro- or vibro-tactile stimulations were used in the past to provide sensory information in many different applications ranging from human manual control to prosthetics. The two modalities were used separately in the past, and we hypothesized that a hybrid vibro-electrotactile (HyVE) stimulation could provide two afferent streams that are independently perceived by a subject, although delivered in parallel and through the same skin location. We conducted psychophysical experiments where healthy subjects were asked to recognize the intensities of electroand vibro-tactile stimuli during hybrid and single modality stimulations.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?