Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Although the concordance between cerebrospinal fluid (CSF) Alzheimer's disease (AD) biomarkers and amyloid-PET findings is well known, there are no data regarding the concordance of amyloid-PET with inconclusive CSF values of amyloid-β (Aβ)1 - 42 and p-tau for the diagnosis of AD.
Objective: To investigate the relationship between the amyloid-PET results with discordant AD biomarkers values in CSF (Aβ1 - 42+/p-tau-or Aβ1 - 42-/p-tau+).
Methods: An observational retrospective study, including 62 patients with mild cognitive impairment (32/62) or dementia (30/62), suspicious of AD who had undergone a lumbar puncture to determine CSF AD biomarkers, and presented discordant values in CSF between Aβ1 - 42 and p-tau (Aβ1 - 42+/p-tau-or Aβ1 - 42-/p-tau+). All of them, underwent an amyloid-PET with 18F-Florbetaben. An extensive neuropsychological testing as part of their diagnostic process (MMSE and TMA-93), was performed, and it was also obtained the Global Deterioration Scale.
Results: Comparing the discordant CSF results of each patient with the cerebral amyloid-PET results, we found that in the group with Aβ1 - 42+ and p-tau-CSF values, the amyloid-PET was positive in 51.2% and negative in 48.8% of patients, while in the group with Aβ1 - 42-and p-Tau+ CSF values, the amyloid-PET was positive in 52.6% of patients and negative in 47.4% of them. No significant association was found (p = 0.951) between the results of amyloid-PET and the two divergent groups in CSF.
Conclusions: No significant relationship was observed between the results of discordant AD biomarkers in CSF and the result of amyloid-PET. No trend in amyloid-PET results was observed in relation to CSF biomarker values.