Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Introduction: Medium cut-off (MCO) membranes may be able to remove middle-large uremic toxins that are retained in the body, which has been linked to various risk factors including malnutrition-inflammation score (MIS). The effect of MCO dialyzers on MIS has been studied.
Methods: This single-center exploratory prospective observational study enrolled maintenance hemodialysis patients who underwent dialysis using either MCO (Theranova 400) or high-flux (FX80) membranes as part of their regular care. Measurements of MIS, body weight, height, body mass index, and various biochemical markers were taken at the beginning and conclusion of the study.
Results: This study included 50 patients who were treated with either the Theranova 400 (n = 25) or the FX80 (n = 25) for a period of 6 months. The two groups were similar in terms of demographics, duration of hemodialysis treatment, and baseline biochemical test results. Theranova 400 had no significant impact on the median MIS (6 [6-10] vs. 7 [5-10], p 0.575) and serum albumin levels (4.07 [3.92-4.22] vs. 4.04 [3.85-4.30], p 0.689), while the FX80 resulted in a significant increase in MIS (6 [5-8] vs. 8 [6-10], p 0.033) and a significant decrease in serum albumin levels (4.23 [4.03-4.36] vs. 3.98 [3.77-4.12], p 0.027) at the end of the study.
Discussion/conclusion: After 6 months of treatment, the MCO dialyzer did not demonstrate a statistically significant difference in the MIS when compared to the high-flux dialyzer. However, MIS worsening was significantly less in the MCO group, indicating the potential benefits of MCO membranes in maintaining nutritional status. Further research is required to validate these results.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1159/000535268 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!