Fiber sizing is one of the most important components in manufacturing composites by affecting mechanical properties, including strength and stiffness. The sizing of manmade fibers offers many advantages, such as improving fiber/matrix adhesion and bonding properties, protecting fiber surfaces from damage during the processing and weaving stages, and enhancing the surface wettability of polymer matrices. In this work, the influence of fiber sizing levels on carbon fibers' (CFs) mechanical properties is reported at room temperature using single fiber tensile testing (Favimat+), single fiber pullout testing (SFPO), and interfacial elemental analysis by X-ray photoelectron spectroscopy (XPS). Standard modulus CFs (7 ± 0.2 μm in diameter) were sized using two commercially available Michelman sizing formulations. The average solid content for each sizing formulation was 26.3 ± 0.2% and 34.1 ± 0.2%, respectively. HEXION RIMR 135 with curing agent RIMH 137 was used as a model thermoset epoxy matrix during SFPO measurements. A predictive engineering fiber sizing methodology was also developed. Sizing amounts of 0.5, 1, and 2 wt.% on the fiber surface were achieved for both sizing formulations. For each fiber size level, 50 single-fiber tensile testing experiments and 20 single-fiber pull-out tests were conducted. The ultimate tensile strength () of the carbon fibers and the interfacial shear strength () of the single fiber composite were analyzed. The sizing levels' effect on interfacial shear stress and the O/C (Oxygen/Carbon) surface composition ratio was investigated. Based on our experimental findings, an increase of 6% in fiber performance was recorded for ultimate tensile and interfacial shear strengths. As a result, generalized fiber sizing and characterization methods were established. These developed methods can be used to characterize the strength and interfacial shear strength of manmade fibers with different sizing formulations and solid contents irrespective of the matrix, i.e., thermoset or thermoplastic.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10747998 | PMC |
http://dx.doi.org/10.3390/polym15244678 | DOI Listing |
Int J Biol Macromol
January 2025
MEMS and Nanotechnology Laboratory, School of Mechanical Engineering, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea; Advanced Medical Device Research Center for Cardiovascular Disease, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea; Center for Next-Generation Sensor Research and Development, Chonnam National University, 77 Yongbong-ro, Buk-gu, Gwangju 61186, Republic of Korea. Electronic address:
Critical-sized bone defects in osteosarcoma treatment demand multifunctional scaffolds that must effectively integrate two key functions, promoting osteogenesis and delivering targeted chemoprevention. This study introduces a dual-component system featuring pH-responsive hydrogels and hydroxyapatite-based fiber-reinforced biomimetic scaffolds designed for controlled and localized curcumin delivery, while addressing its solubility and stability issues. The hydrogel system comprises a double network of polyacrylic acid, sodium alginate, carboxymethyl cellulose, and potato starch, specifically modified to encapsulate curcumin.
View Article and Find Full Text PDFpH is an important physiological parameter within organisms, playing a crucial role in functional activities in cells and tissues. Among various pH sensing methods, optical fiber pH sensors have gained a wide attention due to their unique advantages. However, current silica optical fiber-based pH sensors face some challenges such as weak biocompatibility, low biological safety, complex or unstable surface modification.
View Article and Find Full Text PDFCureus
December 2024
Cornea and Refractive Surgery, Al-Shifa Trust Eye Hospital, Rawalpindi, PAK.
Background: Glaucoma, particularly open-angle glaucoma (OAG), is a leading cause of irreversible blindness, associated with optic nerve damage, retinal ganglion cell death, and visual field defects. Corneal biomechanical properties and cellular components, such as corneal nerve and keratocyte densities assessed by in vivo confocal microscopy (IVCM), may serve as biomarkers for glaucoma progression. This study aimed to explore the relationship between corneal nerve parameters, keratocyte density, and optical coherence tomography (OCT)-derived retinal nerve fiber layer (RNFL) thickness in primary open-angle glaucoma (POAG) patients and controls.
View Article and Find Full Text PDFHeliyon
January 2025
Department of Food Science and Technology, Faculty of Agriculture, Ferdowsi University of Mashhad, Mashhad, Iran.
The applicability of cellulose and its derivatives is greatly depends on their attributes such as aspect ratio, morphology, surface chemistry, crystallinity, as well as their thermal and mechanical properties. However, these attributes can alter according to the utilized raw material, size classifications, extraction techniques, or fibrillation methods. Among these, the effect of raw material particle size on cellulose properties has received limited attention in scientific studies.
View Article and Find Full Text PDFAnal Chem
January 2025
College of Chemistry, Beijing Normal University, Beijing 100875, China.
5-Hydroxyindoleacetic acid (5-HIAA), a vital metabolite of serotonin (5-HT), is crucial for understanding metabolic pathways and is implicated in various mental disorders. In situ monitoring of 5-HIAA is challenging due to the lack of affinity ligands and issues with electrochemical fouling. We present an advanced sensing approach that integrates customizable molecular imprinting polymer (MIP) with self-driven galvanic redox potentiometry (GRP) for precise, real-time in vivo monitoring of 5-HIAA.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!