A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Electromagnetic Detection System with Magnetic Dipole Source for Near-Surface Detection. | LitMetric

This paper proposes a nondestructive, separate transmitter-receiver (TX-RX) electromagnetic measurement system for near-surface detection. Different from the traditional dual-coil integrated design, the proposed transient electromagnetic (TEM) system performs shallow subsurface detection using independent TX coil and movable RX coils. This configuration requires a large primary field so that the far-away secondary field is able to generate reliably induced voltages. To achieve this goal, a bipolar current-pulsed power supply (BCPPS) with a late resonant charging strategy is designed to produce a sufficiently large magnetic moment for the exciting coil with low source interference. The magnetic dipole source (MDS) with a large proportion of weight is separated from the field observation device and does not need to be dragged or transported during the detection process. This setup lowers the weight of the scanning device to 3 kg and greatly improves the measurement efficiency. The results of the laboratory test verify the effectiveness of the separate MDS and RX module system. Field experimental detection further demonstrates that the proposed system can realize highly efficient and shallow surface detection within a 200 m range of the MDS device.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10748061PMC
http://dx.doi.org/10.3390/s23249771DOI Listing

Publication Analysis

Top Keywords

magnetic dipole
8
dipole source
8
near-surface detection
8
detection
6
system
5
electromagnetic detection
4
detection system
4
system magnetic
4
source near-surface
4
detection paper
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!