Aerosol insecticides are widely used in stored product insect management programs in food facilities. Previous research has shown spatial variation in aerosol efficacy within facilities, but information on how spatial patterns of aerosol droplet concentration, size distribution, dispersal, and deposition contribute to this variation in efficacy is limited. This study involved two aerosol application systems: a high-pressure cylinder containing TurboCide Py-75 with pyriproxyfen IGR (ChemTech Ltd., Des Moines, IA, USA) and a hand-held fogger containing Pyrocide 100 (MGK, Minneapolis, MN, USA) with Diacon II which contains methoprene IGR (Wellmark, Schaumburg, IL, USA). These systems were used at single or multiple application locations. The spray trials were conducted in a small-scale flour mill, Hall Ross Flour Mill (Kansas State University, Manhattan, KS, USA). The droplet size distributions were monitored at multiple positions within the room using nine aerodynamic particle sizing (APS, TSI Incorp, Shoreview, MN, USA) instruments. The APS data collected over the treatment period were summarized into a mass concentration index (MCI), which ranged from 155 to 2549 mg/m for Turbocide and 235-5658 mg/m for Pyrocide. A second parameter called the Deposition Index (Dep.Idx) was derived to estimate potential insecticide depositions on the floor and has units of g/m. The Dep.Idx was below 5.3 g/m for most Turbocide applications, while the Dep.Idx was below 8.4 g/m for most Pyrocide applications. The MCI and Dep.Idx values varied with APS position and spray application location, with proximity to the aerosol application location and degree of obstruction between the release point and APS position contributing to this variation. We assessed the relationship between aerosol droplet parameters and insect efficacy using Jacqueline DuVal, the confused flour beetle. The adults were treated directly, while the larvae were treated two weeks later during the residual test (previously published). For Turbocide, efficacy against adults increased with MCI and Dep.Idx values, but for residual efficacy of the IGR, efficacy was high at all aerosol droplet values, so no relationship was apparent. In contrast, the relationship between Pyrocide deposition and adult insect efficacy was highly variable. But with larval insect efficacy, residual larvae control was directly related to increases in Pyrocide MCI and Dep.Idx. Contour plots of Dep.Idx values were developed, which could be used to predict areas of the mill that are not receiving an adequate application rate, and this could be used to develop more effective application strategies for aerosol insecticides in food facilities.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10744046 | PMC |
http://dx.doi.org/10.3390/insects14120914 | DOI Listing |
Sci Total Environ
January 2025
Direction Milieux et impacts sur le vivant, Institut National de l'Environnement Industriel et des Risques (INERIS), Verneuil en Halatte, France.
Emissions due to tires retread/repair and incineration are a cause of concern owing to the presence of nanoparticles in the products. The assessment exposure to humans hereto related is a challenge in an environmental context. The first object of this work is to develop a method to characterize the emission sources using online (counting and sizing) and offline measurements.
View Article and Find Full Text PDFFood Environ Virol
January 2025
Ōmura Satoshi Memorial Institute, Kitasato University, 5-9-1 Shirokane, Minato-Ku, Tokyo, 108-8641, Japan.
Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) and influenza A virus are primarily transmitted through droplets or aerosols from patients. The inactivation effects of existing virus control techniques may vary depending on the environmental factors. Therefore, it is important to establish a suitable evaluation system for assessing virus control techniques against airborne viruses for further real-world implementation.
View Article and Find Full Text PDFACS ES T Eng
January 2024
Department of Chemical and Environmental Engineering, University of Cincinnati, Cincinnati, Ohio 45221, United States.
The COVID-19 pandemic has resulted in significant changes in our daily lives, including the widespread use of face masks. Face masks have been reported to reduce the transmission of viral infections by droplets; however, improper use and/or treatment of these masks can cause them to be contaminated, thereby reducing their efficacy. Moreover, regular replacement of face masks is essential to maintaining their effectiveness, which can be challenging in resource-limited healthcare settings.
View Article and Find Full Text PDFJ Aerosol Sci
November 2024
National Institute for Occupational Safety and Health, Centers for Disease Control and Prevention, Cincinnati, OH, 45226, United States.
Trace measurement of aerosol chemical composition in workplace atmospheres requires the development of high-throughput aerosol collectors that are compact, hand-portable, and can be operated using personal pumps. We describe the design and characterization of a compact, high flow, Turbulent-mixing Condensation Aerosol-in-Liquid Concentrator (TCALC) that allows direct collection of aerosols as liquid suspensions, for off-line chemical, biological, or microscopy analysis. The TCALC unit, measuring approximately 12 × 16 × 18 cm, operates at an aerosol sample flowrate of up to 10 L min, using rapid mixing of a hot flow saturated with water vapor and a cold aerosol sample flow, thereby promoting condensational growth of aerosol particles.
View Article and Find Full Text PDFAnal Chem
December 2024
School of Chemistry, University of Bristol, Bristol BS8 1TS, United Kingdom.
Aerosol droplets are unique microcompartments containing microscopic amounts of material and exhibiting surprising chemical reactivity. Although a diverse set of tools exists to characterize the chemical composition of individual submicron particles in air, comparatively fewer approaches can chemically analyze individual, airborne picolitre droplets. We describe a novel approach for mass spectrometric analysis of individual aqueous picolitre droplets (∼2-180 pL volume) containing down to ∼1 pg analyte mass per droplet.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!