Aim: Conventional management of popliteal artery aneurysms (PAA) through a medial approach may be lon term ineffective. We report our long term rate of continued sac perfusion after ligation and bypass, combined to duplex ultrasound (DUS) surveillance protocol.

Patients And Methods: Follow-up data of 24 PAA (mean diameter 37.5 ± 8.8 mm) treated by ligation and bypass with eventual adjunctive procedures (direct sac embolization or resection) were collected. The endpoints of the study were the long term rate of continued sac perfusion and the freedom from any reintervention.

Results: Twentyfour PAA were treated in 20 patients. Long term follow-up was complete for 19 graft (79.1%). During a median follow-up of 71.2 months (4-168), persistent sac flow was found in 5 legs (26.3%), 4 to 36 months after surgery, without enlargement or rupture. The cumulative Kaplan-Meier survival free from PAA reperfusion at 1, 3, and 6 years was 91.5%, 77.5%, and 71.5%, respectively. Basing on DUS surveillance, late additional procedures were required in 5 patients (25%), to treat sac reperfusion or preserve graft patency. The cumulative Kaplan-Meier survival free from any reintervention at 1, 3, and 6 years was 91.5%, 72.8%, and 67%, respectively.

Conclusions: Conventional management of PAA through a medial approach may be associated to progressive sac expansion. The DUS surveillance protocol remains strongly recommended to detect sac perfusion and suggest the timing of reintervention before rupture occurs. Adjunctive intraoperative procedures could improve the long term results, but further studies on large series are needed.

Key Words: Acrylic glue, Duplex ultrasound study, Femoropopliteal bypass, Popliteal artery aneurysm, Ultrasoundguided embolization.

Download full-text PDF

Source

Publication Analysis

Top Keywords

sac perfusion
16
long term
16
continued sac
12
popliteal artery
12
ligation bypass
12
duplex ultrasound
12
dus surveillance
12
artery aneurysms
8
conventional management
8
paa medial
8

Similar Publications

A Novel Machine Perfusion System for Enhancing Hepatic Microcirculation Perfusion.

Artif Organs

December 2024

Hubei Provincial Clinical Research Center for Natural Polymer Biological Liver, Hubei Key Laboratory of Medical Technology on Transplantation, National Quality Control Center for Donated Organ Procurement, Transplant Center of Wuhan University, Institute of Hepatobiliary Diseases of Wuhan University, Zhongnan Hospital of Wuhan University, Wuhan, Hubei, China.

Background: Machine perfusion is a promising strategy for safeguarding liver transplants donated after cardiac death (DCD). In this study, we developed and validated a novel machine perfusion approach for mitigating risk factors and salvaging severe DCD livers.

Methods: A novel hypothermic oxygenated perfusion (HOPE) system was developed, incorporating two pumps and an elastic water sac to emulate the functionality of the cardiac cycle.

View Article and Find Full Text PDF

Successful laparoscopic management of strangulated left paraduodenal hernia: A case report and review of minimally invasive approaches.

Int J Surg Case Rep

December 2024

Department of Surgery, HRH Princess MahaChakri Sirindhorn Medical Center, Faculty of Medicine, Srinakharinwirot University, 62 Ongkharak, Nakhon Nayok 26120, Thailand. Electronic address:

Introduction: Paraduodenal hernias are rare congenital anomalies that can lead to acute bowel obstruction and strangulation. Laparoscopic management of these complex cases in emergency settings remains challenging, particularly when bowel ischemia is present.

Case Presentation: We report a case of a 56-year-old woman presenting with acute small bowel obstruction due to a strangulated left paraduodenal hernia.

View Article and Find Full Text PDF

Developing a Carotid Pseudoaneurysm Model in Swine.

J Endovasc Ther

November 2024

Division of Vascular and Endovascular Surgery, Mayo Clinic, Rochester, MN, USA.

Background: Traumatic carotid artery pseudoaneurysms (PSAs) represent a vascular anomaly with potential for serious complications, including stroke. Traditional treatments involve endovascular stenting, which may not be ideally suited to otherwise healthy vessels that have the potential to remodel. Given the limitations of smaller animal models in replicating human vasculature and the need for improved treatment modalities, this study introduces a novel swine model for the creation and evaluation of carotid PSAs.

View Article and Find Full Text PDF
Article Synopsis
  • - Hemorrhage is the main cause of preventable death in trauma situations, leading to military and civilian advancements in medical practices, particularly through the use of tourniquets to manage extremity bleeding and save lives.
  • - While tourniquets have significantly decreased deaths from bleeding in military settings, noncompressible hemorrhage still poses a major risk, especially before patients receive definitive medical care.
  • - The study explores using a small, disposable pressure monitor during resuscitative endovascular balloon occlusion of the aorta (REBOA) to enhance blood pressure monitoring, facilitate better resuscitation practices, and reduce the need for blood products in extreme environments.
View Article and Find Full Text PDF

Role of multilayer flow modulator stents in the treatment of arterial aneurysms.

Ther Adv Cardiovasc Dis

October 2024

Antalya Provincial Health Directorate, Antalya, Turkey.

Arterial aneurysms remain a significant public health problem because they often result in death when ruptured; therefore, they require immediate medical treatment. Endovascular aneurysm repair (EVAR) has recently become the primary treatment option, owing to the fewer side effects compared to those with open surgery. However, stents used for conventional EVAR often cause side-branch occlusion, which alters the perfusion of vital organs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!