Background: Long and thin shaft electrodes are implanted intracerebrally for stereoelectroencephalography (SEEG) in patients with pharmacoresistant focal epilepsies. Two adjacent contacts of one of such electrodes can deliver a train of single pulse electrical stimulations (SPES), and evoked potentials (EPs) are recorded on other contacts. In this study we assess if stimulating and recording on the same shaft, as opposed to different shafts, has an impact on common EP features.

New Method: We leverage the large volume of SEEG data gathered in the F-TRACT database and analyze data from nearly one thousand SEEG implantations in order to verify whether stimulation and recording from the same shaft influence the EP pattern.

Results: We found that when the stimulated and the recording contacts were located on the same shaft, the mean and median amplitudes of an EP are greater, and its mean and median latencies are smaller than when the contacts were located on different shafts. This effect is small (Cohen's d ∼ 0.1), but robust (p-value < 10) across the SEEG database.

Comparison With Existing Method(s): Our study is the first one to address this question. Due to the choice of commonly used EP features, our method is congruent with other studies.

Conclusions: The magnitude of the reported effect does not obligate all standard analyses to correct for it, unless they aim at high precision. The source of the effect is not clear. Manufacturers of SEEG electrodes could examine it and potentially minimize the effect in their future products.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jneumeth.2023.110035DOI Listing

Publication Analysis

Top Keywords

single pulse
8
pulse electrical
8
recording shaft
8
contacts located
8
seeg
6
shaft
5
seeg electrode
4
electrode shaft
4
shaft amplitude
4
amplitude latency
4

Similar Publications

A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves.

Sensors (Basel)

January 2025

Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.

(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.

View Article and Find Full Text PDF

Comparison of COVID-19 and Non-COVID-19 Tracheostomised Patients: Complications, Survival, and Mortality Risk Factors.

J Clin Med

January 2025

Otorhinolaryngology Department, Hospital Universitari de Bellvitge, Carrer de la Feixa Llarga, s/n, L'Hospitalet de Llobregat, 08907 Barcelona, Spain.

To compare the outcomes of tracheostomised COVID-19 patients with non-COVID-19 tracheostomised patients to identify factors influencing severity and mortality. A retrospective, single-centre cohort study was conducted on COVID-19 tracheostomised patients admitted from May 2020 to February 2022, compared with a cohort of non-COVID-19 tracheostomised patients. COVID-19 tracheostomised patients had a higher mortality rate (50% vs.

View Article and Find Full Text PDF

: Accurate and reproducible spleen volume measurements are essential for assessing treatment response and disease progression in myelofibrosis. This study evaluates techniques for measuring spleen volume on abdominal MRI. : In 20 patients with bone marrow biopsy-proven myelofibrosis, 5 observers independently measured spleen volume on 3 abdominal MRI pulse sequences, 3D-spoiled gradient echo T1, axial single-shot fast spin echo (SSFSE) T2, and coronal SSFSE T2, using ellipsoidal approximation, manual contouring, and 3D nnU-Net model-assisted contouring comparing coefficients of variation.

View Article and Find Full Text PDF

Heart rate variability biofeedback (HRV BF) training aids adaptation to new climatic, geographical, and social environments. Neurophysiological changes during the HRV BF in individuals from tropical regions studying in the Arctic are not well understood. The aim of this study was to research electroencephalographic (EEG) changes during a single short-term HRV BF session in Indian and Russian students studying in the Russian Arctic.

View Article and Find Full Text PDF

C-UHTC is an ideal aerospace material because of its exceptional properties, but its machinability is facing great challenges. Electrical discharge machining (EDM) offers a potential solution, but its removal mechanism remains unclear, lacking reliable prediction tools to guide the actual production. This paper deeply explores the EDM removal mechanism of C-ZrB-SiC through single-pulse experiments, high-speed camera observations, and thermal-fluid coupling simulations, revealing key processes like heat transfer, phase transformation, molten pool dynamics, crater formation, and reinforcing phase effects.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!