A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Reduction of the Femoral Head First, and Assembly of the MUTARS Device in Case of Impossible Reduction during Total Hip Arthroplasty. | LitMetric

Reduction of the Femoral Head First, and Assembly of the MUTARS Device in Case of Impossible Reduction during Total Hip Arthroplasty.

Hip Pelvis

Department of Orthopaedic Surgery, Inje University Haeundae Paik Hospital, College of Medicine, Inje University, Busan, Korea.

Published: December 2023

Dislocation after a total hip arthroplasty occurs in approximately 1% of patients; however, the frequency is much higher after revision surgery. To prevent dislocation, use of a larger femoral head is recommended, and a dual mobility femoral head has been introduced. However, reducing the dual mobility femoral head to the acetabular component is difficult in cases involving contracture in the soft tissue around the joint. A 72-year-old male patient who developed a periprosthetic joint infection underwent two-stage revision surgery using MUTARS. Two months after the revision, the hip joint became dislocated and manual reduction was attempted; however, dislocation occurred again. During another revision using a dual mobility bearing, the soft tissue around the hip joint was too tight to reduce. The problem was overcome by first repositioning the dual mobility head into the acetabular socket, followed by assembly of the diaphyseal portion of the implant.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10728048PMC
http://dx.doi.org/10.5371/hp.2023.35.4.277DOI Listing

Publication Analysis

Top Keywords

femoral head
16
dual mobility
16
total hip
8
hip arthroplasty
8
revision surgery
8
mobility femoral
8
head acetabular
8
soft tissue
8
hip joint
8
head
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!