A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clues of incomplete reversal of heparin in cardiac surgery. | LitMetric

Objectives: In our center, an unusual rate of patients had abnormalities of hemostasis in immediate postoperative period of cardiac surgery. Our objectives were to identify the cause of these sudden hemostasis abnormalities and to evaluate the performances of point of care coagulation testing.

Methods: In this prospective and descriptive study, we included 33 consecutive patients undergoing elective cardiac surgery for 1 month. Heparin-induced anticoagulation and calculation of the protamine dose were tested by the Hemostasis Management System Plus device (Medtronic, Minneapolis, MN, USA). Fifteen minutes after the end of the protamine infusion, activated clotting time (ACT), activated partial thromboplastin time and anti Xa activity were measured. In case of unusual clinical bleeding, a Quantra analysis (Stago, HemoSonics LLC, Charlottesville, VA) was added.

Results: Residual antiXa activity >0.2 IU/mL after neutralization was present in 44% of patients. Our investigation concluded incomplete heparin reversal. There was no association between cellular reinfusate and the presence of heparin. The unusual rate of hemostasis abnormalities was explained by a less efficient protamine reversal of heparin. ACT and Clot Time Ratio (CTR, Quantra system) correlated with AntiXa with Spearman's coefficients of 0.85 ( < .0001) and 0.95 ( = .0012), respectively. About ACT, a threshold of 150 seconds had a sensitivity of 85% [58-97] and a specificity of 85% [58-97%] for detection of AntiXa>0.2. For CTR, a threshold of 1.4 had a sensitivity of 67% [30-94] and a specificity of 100% [18-100].

Conclusion: The use of point of care coagulation testing is effective in detecting incomplete reversal of heparin.

Download full-text PDF

Source
http://dx.doi.org/10.1177/02676591231160268DOI Listing

Publication Analysis

Top Keywords

reversal heparin
12
cardiac surgery
12
incomplete reversal
8
surgery objectives
8
unusual rate
8
hemostasis abnormalities
8
point care
8
care coagulation
8
heparin
5
clues incomplete
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!