A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

PRESERFLO MicroShunt implantation versus trabeculectomy for primary open-angle glaucoma: a two-year follow-up study. | LitMetric

Background: To compare the intermediate-term efficacy of PRESERFLO (PF) MicroShunt implantation with trabeculectomy (TE) in patients with primary open-angle glaucoma, focusing on longitudinal changes of functional and structural parameters.

Methods: This retrospective comparative study included 104 eyes of 104 patients who underwent TE and 83 eyes of 83 patients that underwent PF implantation between January 2019 and December 2020, with a minimum follow-up of two years. Baseline and postoperative intraocular pressure (IOP), number of IOP-lowering medications, visual field mean defect (MD) and peripapillary retinal nerve fibre layer (RNFL) thickness measured using optical coherence tomography were assessed and compared between groups.

Results: Baseline characteristics (age, sex, IOP, number of IOP-lowering medications, MD, RNFL thickness) were comparable between the two groups (all P > 0.05). During the two-year of follow-up, mean IOP decreased from 24.09 ± 1.15 mmHg and 21.67 ± 0.77 mmHg to 11.37 ± 1.13 mmHg (P < 0.001) and 15.50 ± 1.54 mmHg (P = 0.028), and the mean number of IOP-lowering medications decreased from 3.25 ± 0.14 and 3.51 ± 0.14 to 0.53 ± 0.14 (P < 0.001) and 1.06 ± 0.43 (P < 0.001) in the TE and PF groups, respectively. MD remained stable [- 11.54 ± 0.93 dB and - 11.17 ± 1.66 to - 10.67 ± 0.91 dB (P = 0.226) and - 10.40 ± 4.75 dB (P = 0.628) in the TE and PF groups, respectively] but RNFL thickness decreased continuously during follow-up [62.79 ± 1.94 µm and 62.62 ± 2.05 µm to 57.41 ± 1.81 µm (P < 0.001) and 60.22 ± 1.98 µm (P = 0.182) in the TE and PF groups, respectively].

Conclusion: PF implantation is comparably effective in the intermediate term in lowering IOP and reducing the use of IOP-lowering medications over a two-year follow-up period. Although visual field defects were stable, RNFL continued to decrease during postoperative follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10734133PMC
http://dx.doi.org/10.1186/s40662-023-00369-8DOI Listing

Publication Analysis

Top Keywords

preserflo microshunt
8
microshunt implantation
8
primary open-angle
8
open-angle glaucoma
8
two-year follow-up
8
patients underwent
8
iop number
8
number iop-lowering
8
iop-lowering medications
8
rnfl thickness
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!