Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Purpose: This study evaluated the long-term push-out bond strength (PBS) and nanoleakage (NL) of universal adhesives with different photo-initiator systems in the root canals of teeth in which fiber posts were luted.
Materials And Methods: One-hundred twenty endodontically treated human premolars were randomly divided into 12 groups based on the following factors: adhesives (Scotchbond Universal [SBU], Ambar Universal [AMB], and Ambar Universal APS [AMB-APS]); adhesive strategy (etch-and-rinse and self-etch), and time of testing (immediately vs after 2 years). The posts were cemented, sectioned into slices, tested for PBS at 0.5 mm/min, and examined for NL using scanning electron microscopy immediately thereafter or after 2 years of water storage. Data were evaluated using a four-way ANOVA (root thirds vs time vs universal adhesive vs adhesive strategies) and Tukey's test (α = 5%).
Results: For both evaluation times, AMB-APS demonstrated no significant difference in the PBS or NL when different radicular thirds were compared (p > 0.05). However, for SBU and AMB, the cervical third demonstrated higher PBS and lower NL than those of the apical third at both time points (p < 0.0001). AMB-APS exhibited higher PBS and lower NL in the apical third in comparison with SBU and AMB (p < 0.0001). SBU and AMB displayed a significant decrease in the PBS and increased NL after 2 years (p < 0.0001), whereas AMB-APS demonstrated no significant signs of degradation even after 2 years of water storage (p > 0.05).
Conclusion: Independent of the root third evaluated, the universal adhesive containing APS photo-initiator system demonstrated bonding stability at the adhesive interface between the root canal and fiber posts, even after 2 years of water storage.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.3290/j.jad.b4786551 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!