A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Long-term Evaluation of Dentin Bonding Properties of the Photoinitiator System Contained in Universal Adhesives Used in Fiber-Post Luting Procedures. | LitMetric

Purpose: This study evaluated the long-term push-out bond strength (PBS) and nanoleakage (NL) of universal adhesives with different photo-initiator systems in the root canals of teeth in which fiber posts were luted.

Materials And Methods: One-hundred twenty endodontically treated human premolars were randomly divided into 12 groups based on the following factors: adhesives (Scotchbond Universal [SBU], Ambar Universal [AMB], and Ambar Universal APS [AMB-APS]); adhesive strategy (etch-and-rinse and self-etch), and time of testing (immediately vs after 2 years). The posts were cemented, sectioned into slices, tested for PBS at 0.5 mm/min, and examined for NL using scanning electron microscopy immediately thereafter or after 2 years of water storage. Data were evaluated using a four-way ANOVA (root thirds vs time vs universal adhesive vs adhesive strategies) and Tukey's test (α = 5%).

Results: For both evaluation times, AMB-APS demonstrated no significant difference in the PBS or NL when different radicular thirds were compared (p > 0.05). However, for SBU and AMB, the cervical third demonstrated higher PBS and lower NL than those of the apical third at both time points (p < 0.0001). AMB-APS exhibited higher PBS and lower NL in the apical third in comparison with SBU and AMB (p < 0.0001). SBU and AMB displayed a significant decrease in the PBS and increased NL after 2 years (p < 0.0001), whereas AMB-APS demonstrated no significant signs of degradation even after 2 years of water storage (p > 0.05).

Conclusion: Independent of the root third evaluated, the universal adhesive containing APS photo-initiator system demonstrated bonding stability at the adhesive interface between the root canal and fiber posts, even after 2 years of water storage.

Download full-text PDF

Source
http://dx.doi.org/10.3290/j.jad.b4786551DOI Listing

Publication Analysis

Top Keywords

years water
12
water storage
12
sbu amb
12
universal adhesives
8
fiber posts
8
ambar universal
8
universal adhesive
8
amb-aps demonstrated
8
higher pbs
8
pbs lower
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!