Background: Microbiological diagnosis of pediatric tuberculosis (TB) using conventional microbiological techniques has been challenging due to paucibacillary nature of the disease. Molecular methods using cartridge-based tests like Xpert, have immensely improved diagnosis. A novel next-generation cartridge test, Xpert Ultra, incorporates two additional molecular targets and claims to have much lower detection limit. We attempted to compare the two techniques in presumptive pediatric TB patients.

Objectives: The aim of this study was to compare the diagnostic performance of Xpert MTB/Rif Ultra with Xpert MTB/Rif for the detection of pediatric TB.

Study Design: This is an observational comparative analytical study.

Methods: Children under 15 years of age with presumptive TB were enrolled. Appropriate specimens were obtained (sputum, induced sputum or gastric aspirate for suspected pulmonary TB, cerebrospinal fluid for suspected tubercular meningitis and pleural fluid for suspected tubercular pleural effusion), subjected to smear microscopy, mycobacterial culture, Xpert and Xpert ultra tests and other appropriate diagnostic investigations.

Results: Out of 130 enrolled patients, 70 were diagnosed with TB using a composite reference standard (CRS). The overall sensitivity of Xpert was 64.29% [95% confidence interval (CI) 51.93-75.93%] and that of Xpert Ultra was 80% (95% CI 68.73-88.61%) with 100% overall specificity for both. The sensitivity of Xpert and Xpert Ultra in pulmonary specimens (n = 112) was 66.67% and 79.37% and in extrapulmonary specimens (n = 18) was 42.86% and 85.71%, respectively.

Conclusion: Our study found Ultra to be more sensitive than Xpert for the detection of Mycobacterium tuberculosis in children. Our findings support the use of Xpert Ultra as initial rapid molecular diagnostic test in children under evaluation for TB.

Download full-text PDF

Source
http://dx.doi.org/10.1093/tropej/fmad046DOI Listing

Publication Analysis

Top Keywords

xpert ultra
20
xpert
14
xpert mtb/rif
12
ultra
8
mtb/rif ultra
8
tuberculosis children
8
fluid suspected
8
suspected tubercular
8
xpert xpert
8
sensitivity xpert
8

Similar Publications

Aim: This study aimed to determine the prevalence of microbiologically confirmed female genital tuberculosis (FGTB) infection in patients attending a tertiary care hospital in North India.

Materials And Methods: A total of 623 endometrial biopsy samples were processed in the mycobacteriology laboratory from the outpatient and inpatient gynecology departments between May 2022 and February 2024. Ziehl-Neelsen (ZN) smear was performed on all samples.

View Article and Find Full Text PDF

The absence of an accurate reference test complicates the evaluation of tuberculosis (TB) diagnostic tests among people living with Human Immunodeficiency Virus (PLWHIV). The objective of this study was to estimate (using Bayesian latent class models [BLCM]) the sensitivity (Se), specificity (Sp) and negative and positive predictive values (NPV and PPV) of sputum smear microscopy (SSM), Xpert Ultra and lipoarabinomannan antigen (LAM) tests for TB among PLWHIV in Nairobi, Kenya. This cross-sectional study enrolled a total of 190 patients aged ≥ 18 years with presumptive TB seeking treatment at the Kibra Community Health Center Comprehensive Care Centre (CCC) clinic between September 2022 and March 2023.

View Article and Find Full Text PDF

Background: Centrifuge-free processing methods support stool Xpert Ultra testing for childhood tuberculosis (TB), but there are limited data on their accuracy, acceptability and usability.

Methods: We conducted a prospective evaluation of stool Xpert Ultra in India, South Africa, and Uganda with three methods: Stool Processing Kit (SPK), Simple One-Step (SOS), and Optimized Sucrose Flotation (OSF). Children <15 years old with presumptive TB had respiratory specimen testing with Xpert Ultra and culture.

View Article and Find Full Text PDF

Diagnostic accuracy of Xpert MTB/RIF Ultra for detecting pulmonary tuberculosis and rifampicin resistance: a systematic review and meta-analysis.

Eur J Clin Microbiol Infect Dis

January 2025

Department of Ultrasound Medicine, Guangdong Provincial Key Laboratory of Major Obstetric Diseases, Guangdong Provincial Clinical Research Center for Obstetrics and Gynecology, The Third Affiliated Hospital, Guangzhou Medical University, Guangzhou, 510150, China.

Background: Public health issues related to tuberculosis still exist. Because Xpert MTB/RIF Ultra is more effective than conventional TB diagnostic techniques are, it is now regarded as an emerging technology. The diagnostic accuracy of Xpert MTB/RIF Ultra for tuberculosis was assessed in this systematic study.

View Article and Find Full Text PDF

Background: Tuberculosis (TB) remains a major cause of infectious disease mortality globally, with significant underdiagnosis perpetuating transmission. Tongue swab analysis has emerged as a promising non-invasive method for pulmonary TB diagnosis. This study evaluates the diagnostic accuracy of the TB-EASY quantitative PCR (qPCR) assay using tongue swab specimens.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!