A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Metal-organic framework-based high-performance column chip for micro gas chromatography: hybrid function for simultaneous preconcentration and separation of volatile organic compounds. | LitMetric

Numerous attempts have been made to replace commercial bulky gas chromatography (GC) systems with compact GC systems for monitoring volatile organic compounds in indoor air. However, recently developed compact GC systems are still too bulky in terms of user convenience, portability, and on-site analysis. Hence, an advanced miniaturization of compact GC systems is needed. Importantly, the small and high-performance gas pretreatment chip devices should be developed for compact GC systems. This paper reports the development of a metal-organic framework (MOF)-coated hybrid micro gas chromatography column chip (hybrid GC chip) capable of preconcentration and separation on harmful volatile organic compounds at low-concentration in one single chip device. The hybrid GC chip, 2 cm × 2 cm in size, was fabricated using a microelectromechanical systems process. The synthesized MOF-5 particles were coated on the inner wall of the fabricated hybrid GC chip and acted as an adsorbent and a stationary phase. The developed hybrid GC chip afforded high preconcentration factors with 1033-1237 and high separation resolutions with 3.8-13.3. The developed column showed good performance as a gas preconcentrator and separation column, and is the first device to perform both roles in one single chip device.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3lc00777dDOI Listing

Publication Analysis

Top Keywords

compact systems
16
hybrid chip
16
gas chromatography
12
volatile organic
12
organic compounds
12
chip
9
column chip
8
micro gas
8
preconcentration separation
8
developed compact
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!