Glaucoma is a leading cause of blindness with no cure, but early treatment and effective monitoring can often slow the progression of the disease. Monitoring of glaucoma is based on the measurement of intra-ocular pressure (IOP) that is a physiological parameter related to the mechanical state and parameters of the eye. Conventionally, diagnosing and assessing the progression of glaucoma is based on the method of measuring IOP discretely at clinics. Recent studies have demonstrated the importance of continuously monitoring IOP for 24 h to elucidate the effect of circadian rhythm. In this work, a metamaterial-inspired electrically-passive sensor-embedded contact lens is presented to monitor the IOP fluctuations based on a first-in-human pilot study. The sensor inside the contact lens is an electrically passive, metamaterial-based resonator that can be measured using a wearable antenna patch. The system has been tested with six healthy volunteers during an experiment to induce deliberate IOP changes via water-loading and placing the individuals in supine position using a recliner seat. The initial data compared with tonometer measurements suggest that the system can be used to assess the variation of IOP continuously.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.clae.2023.102102DOI Listing

Publication Analysis

Top Keywords

contact lens
12
first-in-human pilot
8
pilot study
8
glaucoma based
8
iop
6
study novel
4
novel electrically-passive
4
electrically-passive metamaterial-inspired
4
metamaterial-inspired resonator-based
4
resonator-based ocular
4

Similar Publications

A woman in her 50s underwent simple limbal epithelial transplantation (SLET) in the left eye for chemical injury with total limbal stem cell deficiency. A seroma, a hitherto unreported complication of the procedure was noted on the 10th postoperative day. It was associated with an accumulation of inflammatory cells and exudates in the inferior part of the amniotic membrane resembling a hypopyon.

View Article and Find Full Text PDF

Purpose: To determine the countrywide prevalence of dry eye disease (DED) at the population level in Spain, and associated risks.

Methods: This was a cross-sectional study based on a telephone survey conducted in 2022. Participants from the general population were selected by sex, age, region, and population of residence to ensure the representativeness of the Spanish population.

View Article and Find Full Text PDF

Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.

Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.

View Article and Find Full Text PDF

Quantifying tear exchange during rigid contact lens wear using corneoscleral profilometry: A proof of concept study.

Ophthalmic Physiol Opt

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Queensland, Australia.

Introduction: Tear exchange during contact lens wear is essential for ocular surface integrity, facilitating debris removal, and maintaining corneal metabolism. Fluorophotometry and fluorogram methods are typically used to measure tear exchange, which require hardware modifications to a slit lamp biomicroscope. This manuscript introduces an alternative method using a corneoscleral profilometer, the Eye Surface Profiler (ESP), to quantify tear exchange during corneal and scleral rigid lens wear by assessing fluorescence intensity changes over time.

View Article and Find Full Text PDF

Perovskite-Based Smart Eyeglasses as Noncontact Human-Computer Interaction.

Adv Mater

January 2025

Key Laboratory of Green Printing, CAS Research/Education Center for Excellence in Molecular Sciences, Institute of Chemistry, Chinese Academy of Sciences (ICCAS), Beijing Engineering Research Center of Nanomaterials for Green Printing Technology, Beijing National Laboratory for Molecular Sciences (BNLMS), Beijing, 100080, P. R. China.

More than 70% of human information comes from vision. The eye is one of the most attractive sensing sites to collect biological parameters. However, it is urgent to develop a cost-effective and easy-to-use approach to monitor eyeball information in a minimally invasive way instead of current smart contact lenses or camera-based eyeglasses.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!