Simultaneous real-time detection of fractional exhaled nitric oxide and end-tidal carbon dioxide by quantum cascade laser absorption spectroscopy.

Spectrochim Acta A Mol Biomol Spectrosc

Key Laboratory of Optical Information Detection and Display Technology of Zhejiang, Zhejiang Normal University, Jinhua 321004, China. Electronic address:

Published: March 2024

The simultaneous detection of fractional exhaled nitric oxide (FeNO) and end-tidal carbon dioxide (ETCO) is of great importance for the distinguishing and diagnosis of asthma and chronic obstructive pulmonary disease (COPD), providing more comprehensive information on respiratory disorders. This work demonstrates a simultaneous ETCO and FeNO detection system based on quantum cascade laser absorption spectroscopy (QCLAS) technology was presented. The system employs wavelength modulation spectroscopy (WMS) technology and the Herriott multi-pass cell, achieving a detection limit of 2.82 ppb for nitric oxide (NO) and 0.05 % for carbon dioxide (CO). Real-time exhalation measurements were performed on volunteers with varying ETCO and FeNO levels, and the results of the test can accurately distinguish whether the corresponding volunteer was healthy, had asthma or COPD. The effect of exhalation flow rate on the concentration of the two gases was explored. A range of expiratory flow rates were tested in the flow rate interval from 1 to 4 L/min, and there was always an inverse relationship between expiratory flow rate and FeNO concentration, but flow rate changes did not affect ETCO concentration. The results indicate that this detection system can simultaneously and effectively measure ETCO and FeNO concentrations in real-time.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2023.123750DOI Listing

Publication Analysis

Top Keywords

flow rate
16
nitric oxide
12
carbon dioxide
12
etco feno
12
detection fractional
8
fractional exhaled
8
exhaled nitric
8
end-tidal carbon
8
quantum cascade
8
cascade laser
8

Similar Publications

The shape characteristics of flow hydrographs hold essential information for understanding, monitoring and assessing changes in flow and flood hydrology at reach and catchment scales. However, the analysis of individual hydrographs is time consuming, making the analysis of hundreds or thousands of them unachievable. A method or protocol is needed to ensure that the datasets being generated, and the metrics produced, have been consistently derived and validated.

View Article and Find Full Text PDF

To validate Palestine's previously derived emergency department quality standards (EDQS) using an e-Delphi survey. A two-round e-Delphi survey validated the EDQS, developed in an earlier study through a literature review and consensus-building among Palestinian emergency medicine and healthcare quality experts. The study purposively sampled 53 emergency department and healthcare quality experts with over 5 years of experience.

View Article and Find Full Text PDF

Purpose: This systematic review aimed to assess the updated literature for the prevention of salivary gland hypofunction and xerostomia induced by non-surgical cancer therapies.

Methods: Electronic databases of MEDLINE/PubMed, EMBASE, and Cochrane Library were searched for randomized controlled trials (RCT) that investigated interventions to prevent salivary gland hypofunction and/or xerostomia. Literature search began from the 2010 systematic review publications from the Multinational Association of Supportive Care in Cancer/International Society of Oral Oncology (MASCC/ISOO) up to February 2024.

View Article and Find Full Text PDF

To evaluate the safety and efficacy of staged coiling followed by flow diverter (FD) in the treatment of ruptured intracranial aneurysms(RIAs). A retrospective analysis was conducted on 20 patients with RIAs treated with staged coiling followed by FD at a single center, between April 2015 and September 2024. Patient demographics, aneurysm characteristics, clinical and imaging outcomes were reviewed.

View Article and Find Full Text PDF

A novel employment of single particle-inductively coupled plasma-mass spectrometry (SP-ICP-MS) was developed, where a microextraction (ME) probe is used to sample nanoparticles from a surface and analyze them in a single analytical step. The effects of several parameters on the performance of ME-SP-ICP-MS were investigated, including the flow rate, choice of carrier solution, particle size, and the design of the microextraction probe head itself. The optimized ME-SP-ICP-MS technique was used to compare the extraction efficiency (EE, defined as the ratio of particles measured to particles deposited on the surface) of the commercial probe head to a newly designed SP polyether ether ketone (PEEK) probe head.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!