AI Article Synopsis

  • A retrospective study analyzed fluoroscopically guided interventions (FGI) and their associated radiation doses, focusing on patients who received cumulative effective doses (CED) greater than 100 mSv.
  • Out of 3,981 patients studied, 132 (about 3%) had CEDs exceeding 100 mSv, with an average dose of 173.5 mSv, particularly affecting older individuals.
  • The findings suggest that while many patients may not experience radiation-related effects due to age or health conditions, there is a significant risk for those undergoing multiple FGIs, particularly highlighting that 23% received high doses in a single procedure.

Article Abstract

Background: The number of fluoroscopically guided interventions (FGI) has increased significantly over time. However, little attention has been paid to possible stochastic radiation effects. The aim of this retrospective study was to investigate the number of patients who received cumulative effective doses over 100 mSv during FGI procedures.

Material And Methods: Five thousand five hundred and fifty four classified FGI procedures were included. Radiation dose data, retrieved from an in-house-dose-management system, was analysed. Effective doses and cumulative effective doses (CED) were calculated. Patients who received a CED > 100 mSv were identified. Radiology reports, patient age, imaging and clinical data of these patients were used to identify reasons for CED ≥ 100 mSv.

Results: One Hundred and thirty two (41.1% female) of 3981 patients received a CED > 100 mSy, with a mean CED of 173.5 ± 84.5 mSv. Mean age at first intervention was 66.1 ± 11.7 years. 81 (61.4%) of 132 were older than 64 years, one patient was < 30 years. 110 patients received ≥ 100 mSv within one year (83.4%), through FGIs: EVAR, pelvic/mesenteric interventions (stent or embolization), hepatic interventions (chemoembolization, TIPSS), embolization of cerebral aneurysms or arterio-venous-malformations.

Conclusions: Substantial CED may occur in a small but not ignorable fraction of patients (~ 3%) undergoing FGIs. Approximately 2/3rd of patients may most likely not encounter radiation-related stochastic effects due to life-threatening diseases and age at first treatment > 65 years but 1/3rd may. Patients undergoing more than one FGI (77%) carry a higher risk of accumulating effective doses > 100 mSv. Remarkably, 23% received a mean CED 162.2 ± 72.3 mSv in a single procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00270-023-03604-wDOI Listing

Publication Analysis

Top Keywords

cumulative effective
12
patients received
12
fluoroscopically guided
8
guided interventions
8
interventions fgi
8
effective doses
8
fgi
5
patients
5
effective dose
4
dose fluoroscopically
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!