A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Refractive Predictability between Standard and Total Keratometry during the Femtosecond Laser-Assisted Cataract Surgery with Monofocal Intraocular Lens with Enhanced Intermediate Function. | LitMetric

Purpose: We aimed to compare the accuracy of the intraocular lens (IOL) calculation formula using the standard keratometry (K) and total K (TK) during the femtosecond laser-assisted cataract surgery (FLACS) with a monofocal IOL with enhanced intermediate function using currently used formulas.

Methods: A retrospective review of 125 eyes from 125 patients who had undergone FLACS with implantation of monofocal IOL with enhanced intermediate function was conducted. The predicted refractive power was calculated using an optical biometer (IOLmaster 700) according to the K and TK in the Barrett Universal II, SRK/T, Haigis, and Holladay 2 formulas. Absolute prediction error (APE) obtained from the actual postoperative refractive outcomes and the refractive error predicted in each formula was compared one month after surgery.

Results: Mean APE ranged between 0.29 and 0.39 diopters (D) regardless of the calculation formula and the method of measuring corneal curvature. Significant differences were observed in the APE from the four formulas and the two keratometric measurements (p = 0.014). In a total of 125 eyes from 125 patients, the mean APE was lowest with the Barrett Universal II formula. Across all formulas, both the mean APE and the median APE tended to be lower for K than for TK, although there was no significant difference. Approximately 70% to 80% of the patients were included within 0.5 D of the refractive error across all formulas. The percentage of eyes within 0.5 D of APE outcomes was not statistically different between the K and TK data when using each formula.

Conclusions: Keratometric measurements considering the poster corneal curvature did not show any additional advantages when implanting the monofocal IOL with enhanced intermediate function during the FLACS.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10869425PMC
http://dx.doi.org/10.3341/kjo.2023.0039DOI Listing

Publication Analysis

Top Keywords

enhanced intermediate
16
intermediate function
16
monofocal iol
12
iol enhanced
12
femtosecond laser-assisted
8
laser-assisted cataract
8
cataract surgery
8
intraocular lens
8
calculation formula
8
125 eyes
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!