Background: Patients with low-flow, low-gradient aortic valve stenosis constitute a substantial subset of all severe aortic stenosis patients. However, assessment of true severity of these patients can be challenging. In this analysis, we study the utility of the common carotid artery waveforms to distinguish true from pseudo-severe low-flow low-gradient aortic stenosis.

Methods: This is an observational analysis that included patients who underwent a transthoracic echocardiogram (TTE) and duplex carotid ultrasonography (DCUS) and had low-flow, low-gradient aortic stenosis with reduced left ventricular ejection fraction (LVEF) on the index TTE (LVEF <50%, calculated aortic valve area [AVA] of ≤1.0 cm, mean and peak gradient of <40 and <64 mm Hg, respectively, and stroke volume index <35 mL/m). Patients were classified as pseudo-severe and true-severe aortic stenosis based on additional subsequent testing. Differences in various TTE and DCUS waveform parameters across the aortic valve and the common carotid artery were compared between the 2 groups.

Results: The study included 30 patients (60 carotid arteries). Fifteen patients were categorized as pseudo-severe and 15 as true severe aortic stenosis. There were no significant differences in calculated AVA, LVEF, stroke volume/stroke volume index, and Doppler Velocity Index in the 2 groups. Mean and peak gradient were higher in patients with true-severe aortic stenosis. Carotid acceleration time (cAT) was significantly prolonged in patients with true-severe compared with pseudo-severe aortic stenosis. A cAT ≥80 ms was 83.3% sensitive and 83.3% specific for true-severe aortic stenosis.

Conclusion: cAT acceleration time may be used to distinguish true from pseudo-severe low-flow, low-gradient aortic valve stenosis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.amjmed.2023.12.005DOI Listing

Publication Analysis

Top Keywords

low-flow low-gradient
16
low-gradient aortic
16
aortic stenosis
12
aortic
5
carotid duplex
4
duplex ultrasonography
4
ultrasonography assess
4
assess severity
4
low-flow
4
severity low-flow
4

Similar Publications

Severe aortic valve stenosis poses a significant risk for the aging population, often escalating from mild symptoms to life-threatening heart failure and sudden death. Without timely intervention, this condition can lead to disastrous outcomes. The advent of transcatheter aortic valve implantation (TAVI) has gained popularity, emerging as an effective alternative for managing severe aortic stenosis (AS) in high-risk patients experiencing deterioration of previously implanted bioprosthetic surgical aortic valves (SAV), which introduces complex challenges such as device compatibility and anatomical considerations.

View Article and Find Full Text PDF

Background: Transthyretin cardiac amyloidosis (ATTRCA) is a prevalent disease, and it can be associated with heart failure (HF), left ventricle hypertrophy (LVH), atrial fibrillation (AF), and aortic stenosis (AS).

Aim: The study aims to detect the prevalence of ATTRCA in the symptomatic AS population.

Method: A single-center prospective study screening for ATTRCA in patients diagnosed with symptomatic severe AS undergoing aortic valve (AV) intervention.

View Article and Find Full Text PDF

Background: Aortic stenosis (AS) is a complex condition with various hemodynamic subtypes, each with distinct clinical profiles and outcomes. This study aimed to assess the characteristics and outcomes of different AS phenotypes based on flow and gradient patterns.

Methods: In this retrospective cohort study, we included 930 patients who underwent transcatheter aortic valve replacement (TAVR) for severe symptomatic AS at Mayo Clinic sites from 2012-2017.

View Article and Find Full Text PDF

Quantifying form resistance is essential for estimating summer low and bankfull flow from stream survey channel morphology.

Geomorphology (Amst)

December 2024

Retired: U.S. Environmental Protection Agency, Office of Research and Development, Center for Public Health and Environmental Assessment, Pacific Ecological Systems Division, 200 SW 35th Street, Corvallis, OR 97333, USA.

Reliable estimates of low flow and flood discharge at ungaged locations are required for evaluating stream flow alteration, designing culverts and stream crossings, and interpreting regional surveys of habitat and biotic condition. Very few stream gaging stations are located on small, remote streams, which typically have complex channel morphology. Adequate gaging is also lacking on larger streams that are remote, smaller than those typically gaged, or have channel morphology not conducive to installation of gages.

View Article and Find Full Text PDF

Background: Low-gradient (LG) aortic stenosis (AS) has not been fully characterized compared with high-gradient (HG) AS in terms of cardiac damage, frailty, aortic valve calcification, and clinical outcomes.

Objectives: The aim of this study was to compare the clinical characteristics and outcomes between each hemodynamic type of LG AS and HG AS.

Methods: The current study included 3,363 patients in the CURRENT AS (Contemporary outcomes after sURgery and medical tREatmeNT in patients with severe Aortic Stenosis) Registry-2 after excluding patients without indexed stroke volume or left ventricular ejection fraction (LVEF) data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!