Purpose: To assess whether: i) a lower amplitude constant-load MOD is appropriate to determine the mean response time (MRT); ii) the method accurately corrects the dissociation in the V̇O 2 -PO relationship during ramp compared with constant-load exercise when using different ramp slopes.

Methods: Eighteen participants (7 females) performed three SRS tests including: i) step-transitions into MOD from 20 to 50 W (MOD 50 ) and 80 W (MOD 80 ); and ii) slopes of 15, 30, and 45 W·min -1 . The V̇O 2 and PO at the gas exchange threshold (GET) and the corrected respiratory compensation point (RCP CORR ) were determined. Two to three 30-min constant-load trials evaluated the V̇O 2 and PO at the maximal metabolic steady state (MMSS).

Results: There were no differences in V̇O 2 at GET (1.97 ± 0.36, 1.99 ± 0.36, 1.95 ± 0.30 L·min -1 ), and RCP (2.81 ± 0.57, 2.86 ± 0.59, 2.84 ± 0.59) between 15, 30, and 45 W·min -1 ramps, respectively ( P > 0.05). The MRT in seconds was not affected by the amplitude of the MOD or the slope of the ramp (range 19 ± 10 s to 23 ± 20 s; P > 0.05). The mean PO at GET was not significantly affected by the amplitude of the MOD or the slope of the ramp (range 130 ± 30 W to 137 ± 30 W; P > 0.05). The PO at RCP CORR was similar for all conditions ((range 186 ± 43 W to 193 ± 47 W; P > 0.05).

Conclusions: The SRS protocol accounts for the V̇O 2 MRT when using smaller amplitude steps, and for the V̇O 2 slow component when using different ramp slopes, allowing for accurate partitioning of the exercise intensity domains in a single test.

Download full-text PDF

Source
http://dx.doi.org/10.1249/MSS.0000000000003362DOI Listing

Publication Analysis

Top Keywords

ramp slopes
8
mod mod
8
rcp corr
8
amplitude mod
8
mod slope
8
slope ramp
8
ramp range
8
ramp
6
mod
6
v̇o
6

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!