A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Magnetically Induced Grid Structure for Enhancing the Performance of a Dual-Mode Flexible Sensor with Tactile/Touchless Perception. | LitMetric

Magnetically Induced Grid Structure for Enhancing the Performance of a Dual-Mode Flexible Sensor with Tactile/Touchless Perception.

ACS Appl Mater Interfaces

Key Laboratory of Optoelectronic Technology & Systems, Ministry of Education, Chongqing University, Chongqing 400044, China.

Published: December 2023

As an advanced sensing technology, dual-mode flexible sensing, integrating both tactile and touchless perception, propels numerous intelligent devices toward a more practical and efficient direction. The ability to incorporate multiple sensing modes and accurately distinguish them in real time has become crucial for technological advancements. Here, we proposed a dual-mode sensing system (B-MIGS) consisting of a dual-layer sensing device with a magnetically induced grid structure and a testing device. The system was capable of utilizing mechanical pressure to perceive tactile stimulation and magnetic sensing to simultaneously transduce touchless stimulation simultaneously. By leveraging the triboelectric effect, the decoupling of tactile and touchless signals in the presence of unknown signal sources was achieved. Additionally, the sensing characteristics of the B-MIGS were optimized by varying the curing magnetic induction intensity and magnetic particle concentration. The influence of the temperature and humidity on the sensing signals was also discussed. Finally, the practical value of the B-MIGS as a dual-mode monitoring system was demonstrated on soft petals and sensor arrays, along with exploration of its potential application in underwater environments.

Download full-text PDF

Source
http://dx.doi.org/10.1021/acsami.3c16240DOI Listing

Publication Analysis

Top Keywords

magnetically induced
8
induced grid
8
grid structure
8
dual-mode flexible
8
sensing
8
tactile touchless
8
structure enhancing
4
enhancing performance
4
dual-mode
4
performance dual-mode
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!