Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Alzheimer's Disease (AD) is one of the most common neurodegenerative disorders in elderly people. It is diagnosed by detecting amyloid beta (Aβ) protein in cerebrospinal fluid (CSF) obtained by lumbar puncture or through expensive positron emission tomography (PET) imaging. Although blood-based diagnosis of AD offers a less invasive and cost-effective alternative, the quantification of Aβ is technically challenging due to its low abundance in peripheral blood. To address this, we developed a compact yet highly sensitive microwell-based electrochemical sensor with a densely packed microelectrode array (20 by 20) for enhancing sensitivity. Employing microwells on the working and counter electrodes minimized the leakage current from the metallic conductors into the assay medium, refining the signal fidelity. We achieved a detection limit <10 fg/mL for Aβ by elevating the signal-to-noise ratio, thus capable of AD biomarker quantification. Moreover, the microwell structure maintained the performance irrespective of variations in bead number, indicative of the sensor's robustness. The sensor's efficacy was validated through the analysis of Aβ concentrations in plasma samples from 96 subjects, revealing a significant distinction between AD patients and healthy controls with an area under the receiver operating characteristic curve (AUC) of 0.85. Consequently, our novel microwell-based electrochemical biosensor represents a highly sensitive platform for detecting scant blood-based biomarkers, including Aβ, offering substantial potential for advancing AD diagnostics.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.bios.2023.115898 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!