Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
This study provides a concise and structured overview of a dosimetric comparison study conducted to assess the feasibility and effectiveness of 4 advanced radiotherapy techniques in treating brain metastases with hippocampus sparing and simultaneous integrated boost (HS-WBRT+SIB). Eleven patients with brain metastases previously treated with radiotherapy were included in the study. Planning CT scans with 2 mm slice thickness and MR imaging were used for contouring and dose prescription. The bilateral hippocampus and other organs at risk (OARs) were automatically contoured, and hippocampal avoidance regions (HAR) were defined as a 7 mm 3D expansion around the hippocampus. Gross tumor volume for each metastasis (GTV) and planning target volume for metastases (PTV) were delineated. The whole-brain CTV (CTV) and planning target volume for whole brain (PTV) were defined accordingly. Treatment planning and optimization were conducted using state-of-the-art radiotherapy techniques: Ethos, HyperArc, VMAT, and Tomotherapy. Tomotherapy achieved the highest D98% for PTV, indicating the best metastasis coverage. HyperArc plans showed the highest D98% for PTV, suggesting superior whole-brain coverage. Tomotherapy demonstrated significantly lower D98%, D2%, and D values for the hippocampus, indicating its superiority in sparing the hippocampus. VMAT resulted in the lowest D2% values for the eyes, optic nerves, brainstem, and hypophysis, showing the best sparing of these critical structures. Tomotherapy consistently achieved lower D values for parotids, oral cavity, and lips compared to the other techniques. The dosimetric comparison revealed distinct strengths and weaknesses for each radiotherapy technique. Tomotherapy excelled in sparing the hippocampus, while VMAT showed promise in sparing OARs. HyperArc plans demonstrated the best overall whole-brain coverage. These findings should guide clinicians in selecting the most suitable technique based on patient characteristics and institutional resources.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.meddos.2023.11.004 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!