Objective: To investigate the influence of 135° and 90° cavity design on quality of margin and marginal adaptation and microleakage of all-ceramic computer aided design/computer aided manufacturing (CAD/CAM) inlays.
Methods: One hundred extracted human molars were prepared by criteria of buccal occlusal (BO) inlay. On the buccal, the mesial margin was prepared as 135° bevel while the distal margin was prepared as butt-joint. All-ceramic restorations were made in the Sirona CEREC AC CAD/CAM system with VitaBlocs Mark Ⅱ, Upcera UP.CAD, IPS e.max CAD, Upcera Hyramic and Lava Ultimate. The gaps between each inlay's mesial margin-abutment and distal margin-abutment were recorded under an optical microscope. Each inlay was adhered to the abutment and aged by thermal cycling for 10 000 times. Each specimen was cut into 3 slices after staining. Dye penetration was evaluated under an optical microscope for mesial and distal margins.
Results: Mean marginal integrity rate, mean marginal gap value and mean depth of microleakage of 135° margin of Group Upcera Hyramic and Lava Ultimate were significantly better than those of Group VitaBlocs Mark Ⅱ, Upcera UP.CAD and IPS e.max CAD( < 0.05). Mean marginal gap value, mean depth of microleakage and scale of mean depth of microleakage of 90° margin of Group Upcera Hyramic and Lava Ultimate were significantly better than those of Group Upcera UP.CAD and IPS e.max CAD ( < 0.05) while mean marginal integrity rate was not significantly different (>0.05). Mean marginal integrity rate of 90° margin was significantly better than that of 135° margin in each group ( < 0.05) while mean depth of microleakage between different margins was not significantly different in each group (>0.05). Mean marginal gap value of 90° margin of Group VitaBlocs Mark Ⅱ and IPS e.max CAD was significantly better than that of 135° margin ( < 0.05) while there was not significant difference in other 3 groups between 90° and 135° margin (>0.05). Scale of mean depth of microleakage of 135° margin of Group Upcera Hyramic and Lava Ultimate was significant better than that of 90° margin ( < 0.05) while there was not significantly different in other 3 groups between 90° and 135° margin (>0.05).
Conclusion: The mesial and distal margins of abutement of all-ceramic inlay should be prepared as butt-joint.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10724004 | PMC |
http://dx.doi.org/10.19723/j.issn.1671-167X.2023.06.023 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!